Failing
item
code
Description/Action
FI02092
See
FI00092
(See
page
FI02112
FI02112
indicates
that
the
addressed
storage
device
is
the
failing
item.
Perform
the
following:
1.
Is
the
device
location
information
available
in
the
Service
Action
Log?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Exchange
the
failing
item.
See
Note:
If
the
failing
item
is
in
a
migration
tower,
go
to
the
recovery
procedures
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
This
ends
the
procedure.
2.
Find
the
IOP
address
and
the
device
address
(see
3.
To
determine
the
location
of
the
I/O
processor
card,
see
the
and
find
the
diagram
of
the
system
unit
or
the
expansion
unit.
Then,
find:
v
The
IOP
card
location
identified
by
the
direct
select
address.
v
The
addressed
storage
device
location
identified
by
the
device
address.
4.
Exchange
the
failing
device.
Use
the
device
type
to
determine
the
part.
Symbolic
FRUs
For
use
by
authorized
service
providers.
Use
the
contents
pane
to
select
the
symbolic
FRU
you
would
like
to
use.
ACMODUL
For
use
by
authorized
service
providers.
An
AC
module
or
power
supply
may
be
failing.
This
procedure
will
help
you
to
determine
the
part
number
for
the
failing
item.
If
the
system
powers
on
normally,
or
stays
powered
on
after
an
ac
power
failure,
no
replacement
of
parts
may
be
needed.
Follow
the
instructions
for
the
model
you
are
working
on:
v
Models
270,
800,
810,
820,
825,
870/890
(FC
9094)
(See
page
v
Models
830,
840,
SB2,
and
SB3
(See
page
ACMODUL
instructions
for
Models
270,
800,
810,
820,
825,
870/890
(FC
9094)
1.
For
Model
825
with
a
reference
code
00AC,
make
sure
that
the
processor
enclosure
cover
is
fully
closed.
Note:
On
a
Model
825,
the
00AC
reference
code
can
be
caused
by
the
processor
enclosure
cover
not
installed,
or
a
faulty
interlock
switch
assembly.
See
the
remove
and
replace
procedure,
and
the
for
the
part
number.
2.
For
Models
870/890
with
reference
code
00AC,
check
the
following
before
continuing
with
this
procedure:
v
When
the
room
EPO
cable
is
not
installed
(on
an
870/890
system
unit),
make
sure
that
the
room
EPO
BYPASS
switch
on
the
bottom
of
the
EPO
panel
is
to
the
left
(blocking
cable
installation).
v
When
the
room
EPO
is
installed,
check
to
ensure
that
the
customer’s
room
EPO
switch
is
not
tripped
and
the
cable
is
connected
and
seated
correctly
(On
an
870/890
system
unit).
v
Check
the
VSCOMM
cable,
BPC-A/B
P00
and
M41
VPD
to
CB1
between
the
FC
9094
and
870/890
system
unit,
to
ensure
that
it
is
connected
and
seated
correctly.
268
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation