Does
the
same
SRC
occur?
v
Yes
:
Continue
with
the
next
step.
v
No
:
If
the
system
IPLs
past
the
original
error,
then
isolate
to
the
failing
IOP
or
IOA
card.
Follow
the
service
actions
for
the
new
SRC.
This
ends
the
procedure.
12.
Remove
and
label
all
of
the
storage
device
units
EXCEPT
for
the
alternate
IPL
load-source
device
unit
you
are
currently
using.
(This
includes
all
of
the
disk
devices
in
D01
-
D12.)
If
the
system
IPLs
past
the
original
error,
then
isolate
to
the
failing
device
unit.
If
the
failure
still
occurs,
replace
the
following
FRUs
one
at
a
time
until
the
problem
is
resolved.
See
the
v
First
storage
IOA
v
System
unit
backplane
in
location
MB1
13.
For
Models
830,
840,
SB2,
or
SB3:
Is
this
system
a
Model
830
with
SB2
system
unit
and
FC
9074?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Go
to
step
16
(See
page
14.
See
Remove
the
IOPs
and
IOAs,
EXCEPT
for
the
load-source
IOP
and
the
first
storage
IOA.
Attempt
to
perform
the
alternate
IPL.
Does
the
same
SRC
occur?
v
Yes
:
Continue
with
the
next
step.
v
No
:
If
the
system
IPLs
past
the
original
error,
then
isolate
to
the
failing
IOP
or
IOA
card.
Follow
the
service
actions
for
the
new
SRC.
This
ends
the
procedure.
15.
Remove
(and
label)
all
of
the
storage
device
units
EXCEPT
for
the
alternate
IPL
load-source
device
unit
that
you
are
currently
using
(This
includes
all
of
the
disk
devices
in
D31-D40
and
D46-D50.)
If
the
system
IPLs
past
the
original
error,
then
isolate
to
the
failing
device
unit.
If
the
failure
still
occurs,
replace
the
following
FRUs
in
order
one
at
a
time
until
the
problem
is
resolved.
See
the
a.
Load
source
IOP
in
location
C01
in
the
FC
9074
base
I/O
tower.
b.
First
storage
IOA
(location
C02,
C03
or
C04)
in
the
FC
9074
base
I/O
tower.
c.
HSL
I/O
bridge
card
in
location
C08
in
the
FC
9074
base
I/O
tower.
d.
Network
interface
controller
(NIC)
card
in
location
M06
in
the
830
system
unit.
e.
Tower
card
in
location
CB1
in
the
FC
9074
base
I/O
tower.
This
ends
the
procedure.
16.
This
is
a
Model
840,
SB3
system
unit
and
FC
9079
base
I/O
tower.
See
Remove
the
IOPs
and
IOAs,
EXCEPT
for
the
load-source
IOP
and
the
first
storage
IOA.
Does
the
same
SRC
occur?
v
Yes
:
Continue
with
the
next
step.
v
No
:
If
the
system
IPLs
past
the
original
error,
then
isolate
to
the
failing
IOP
or
IOA
card.
Follow
the
service
actions
for
the
new
SRC
17.
Remove
(and
label)
all
of
the
storage
device
units
EXCEPT
for
the
alternate
IPL
load-source
device
unit
that
you
are
currently
using.
(This
includes
all
of
the
disk
devices
in
D31-D40
and
D46-D50.)
If
the
system
IPLs
past
the
original
error,
then
isolate
to
the
failing
device
unit.
If
the
failure
still
occurs,
replace
the
following
FRUs
in
order
one
at
a
time
until
the
problem
is
resolved.
See
the
a.
Load
source
IOP
in
location
C01
in
the
FC
9079
base
I/O
tower.
276
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation