The
cache
adapter
card
is
only
a
separate
failing
item
on
migrated
towers.
If
the
cache
adapter
card
is
located
in
a
migrated
tower,
see
the
CACHE
symbolic
FRU
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
for
FRU
isolation
instructions.
CAPPWR
For
use
by
authorized
service
providers.
The
Capacitor
card
(CAP)
may
be
the
failing
item.
1.
Is
the
SRC
1xx1-8468?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Choose
from
the
following
options:
–
If
fewer
than
3
DCAs
are
installed:
-
If
no
capacitor
card
is
installed
in
CAP
1
(M33)
or
CAP
2
(M37)
location,
install
a
card
in
CAP
1
location.
-
If
a
capacitor
card
is
present
in
either
CAP
1
or
CAP
2
location,
reseat
it.
If
the
problem
is
not
fixed,
replace
it.
–
If
3
or
more
DCAs
are
installed:
-
If
no
capacitor
card
is
installed
in
CAP
1
location,
one
is
required.
-
If
a
capacitor
card
is
installed
in
either
CAP
1
location,
reseat
it.
If
the
problem
is
not
fixed,
replace
it.
2.
For
SRC
1xx1-8469:
v
If
no
capacitor
card
is
installed
in
CAP
2
(M37)
location,
install
one.
It
is
required.
v
If
a
capacitor
card
is
installed
in
CAP
2
location,
reseat
it.
If
the
problem
is
not
fixed,
replace
it.
v
See
for
the
part
number.
Note:
Before
replacing
any
field
replaceable
units
(FRUs),
verify
that
the
card
is
seated
correctly.
Table
1.
CAPPWR
for
Models
870
and
890
:
Unit
Reference
Code
CAP
Unit/location
1xx1-
8468
CAP-1/M33
1xx1-
8469
CAP-2/M37
This
ends
the
procedure.
CBLALL
For
use
by
authorized
service
providers.
A
power
cable
may
be
the
failing
item.
When
there
is
a
location
and
part
number
displayed
on
the
Control
Panel
of
a
system
or
expansion
tower,
then
you
are
to
replace
that
FRU
first.
Perform
the
following
to
determine
the
part
number
of
the
failing
part.
1.
Is
the
SRC
1xxx
2201
or
2301?
v
No
:
Continue
with
the
next
step.
v
Yes
:
The
failing
item
is
a
power
cable.
Exchange
the
following
parts
one
at
a
time.
–
Base
backplane
power
cable:
-
PWR3A
if
installed
-
part
44H7809
-
PWR3B
if
installed
-
part
44H7825
–
Tape/Optical/Disk
Unit
power
cable:
298
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation