6.0
meters
-
part
21F9469
–
15.0
meters
-
part
21F9358
–
30.0
meters
-
part
21F9359
–
60.0
meters
-
part
21F9360
–
100.0
meters
(SPCN
optical
cable)
-
part
21F9415
–
SPCN
optical
adapter
-
part
90H6287
–
SPCN
port
cable
(frame-to-node)
-
part
21F9362
–
Frame-to-frame
cable
-
part
87G6235
–
Integrated
xSeries
(TM)
Server
SPCN-Y
cable
assembly
-
part
04N2652
12.
Is
the
SRC
1xxx-2613?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
in
the
Plan
for
hardware
and
software
topic
in
Information
Center,
to
determine
the
power
cable
part
number
for
systems
in
your
country
or
region.
This
information
is
also
available
in
the
book
under
the
Power
topic.
13.
Is
the
SRC
1xxx-8940,
8941,
8942
or
8943?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Go
to
This
ends
the
procedure.
14.
Reseat
the
RS485
cable.
Does
this
correct
the
problem?
Note:
It
may
take
up
to
one
minute
for
the
frame
ID
to
stop
blinking.
v
Yes
:
This
ends
the
procedure.
v
No
:
Continue
with
the
next
step.
15.
Exchange
the
RS485
cable
assembly
part
-
21P4162.
Does
this
correct
the
problem?
Note:
It
may
take
up
to
one
minute
for
the
frame
ID
to
stop
blinking.
v
Yes
:
This
ends
the
procedure.
v
No
:
Go
to
the
next
FRU
in
the
list.
This
ends
the
procedure.
CBLPWR
For
use
by
authorized
service
providers.
A
power
or
AC
line
cord
may
be
the
failing
item.
Use
the
diagram
below
to
view
the
power
cable
locations,
in
conjunction
with
the
tables
below
that
give
more
details.
The
tables
include:
v
Power
cables
(See
page
v
AC
line
cords
(See
page
Figure
1.
Part
locations
for
power
cables
Analyze
hardware
problems
301