b.
Replace
each
card
one
at
a
time,
powering
on
the
system
or
tower
(as
instructed
in
the
remove
and
replace
procedure)
after
you
replace
each
one,
until
the
problem
appears
again.
The
last
card
that
you
replaced
before
the
problem
appeared
again
is
the
failing
item.
Continue
with
the
next
step.
3.
Use
the
links
in
the
table
below
to
locate
and
replace
the
failing
item.
Table
1.
Failing
item
for
symbolic
FRU
PIOCARD
System
model,
tower,
expansion
unit,
or
machine
type
Name
of
FRU
to
exchange
Link
to
locations
information
and
remove
and
replace
procedures
Model
270
(Embedded
IOP
DSA
=
000110xx)
System
unit
backplane
See
You
will
need
the
processor
feature
code
(characters
5
through
8
of
function
20
on
the
control
panel).
Model
270
PCI
IOP
or
IOA
See
You
will
need
the
processor
feature
code
(characters
5
through
8
of
function
20
on
the
control
panel).
Models
800
and
810
System
unit
backplane
See
You
will
need
the
processor
feature
code
(characters
5
through
8
of
function
20
on
the
control
panel).
Models
800
and
810
PCI
IOP
or
IOA
See
Model
820
(Embedded
IOP
DSA
=
000110xx)
System
unit
backplane
See
Model
820
PCI
IOP
or
IOA
See
Model
825
PCI
IOP
or
IOA
See
Models
830
and
SB2
base
I/O
tower
(FC
9074)
PCI
IOP
or
IOA
See
Models
840
and
SB3
base
I/O
tower
(FC
9079)
PCI
IOP
or
IOA
See
Models
870
and
890
PCI
IOP
or
IOA
See
FC
5074
Expansion
I/O
Tower
PCI
IOP
or
IOA
See
FC
5075
Expansion
I/O
Tower
PCI
IOP
or
IOA
See
FC
5078,
FC
0578
Expansion
I/O
Unit
PCI
IOP
or
IOA
See
FC
5079
(1.8m
expansion
tower)
PCI
IOP
or
IOA
See
FC
5088
or
FC
0588
Expansion
I/O
Unit
PCI
IOP
or
IOA
See
FC
5095,
FC
0595
Expansion
I/O
Unit
PCI
IOP
or
IOA
See
External
xSeries
Server
Integrated
xSeries
Adapter
Card
See
This
ends
the
procedure.
PLUS
For
use
by
authorized
service
providers.
416
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation