v
Models
270
and
820
(See
page
v
Models
800
and
810
(See
page
v
Models
830,
840,
SB2,
and
SB3
(See
page
PWRREG
instructions
for
Models
270
and
820
1.
Is
the
SRC
1xxx
1611,
1612,
1613,
1621,
1622
or
1623?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Power
regulator
1
or
2
is
the
failing
item.
Use
Table
6.
Processor
type
numbers
for
Models
270
and
820
(See
page
)
in
symbolic
FRU
CCIN
to
determine
the
processor
type
to
be
replaced.
2.
Is
the
SRC
1xxx
2611?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Choose
from
the
following
(processor
feature
codes
can
be
found
in
control
panel
function
20
and
broken
down
into
CCIN
as
necessary
using
symbolic
FRU
–
For
Processor
feature
code
22A2,
22A4,
22A5,
2301,
2302,
23E7,
23F0,
23F1,
2422
and
2452:
Replace
Regulator
R01
(see
–
For
removable
Processor
feature
code
23A1,
23A2,
23A3,
23A4,
2456,
24AA,
24A9,
24AC,
24AB,
24A8,
249E,
249D,
249C,
249B,
0150:
Replace
regulator
in
processor
M03
daughter
card
(see
–
For
removable
Processor
feature
code
23A9,
23AA,
23AC,
2425,
23B1,
23B2,
23B3,
23B4,
23B5,
23B6,
2426,
0151,
24B5,
24B4,
24B3,
24B2,
24B1,
24B0,
2457,
23B8,
23B9,
23BA,
23BB,
23BC,
23BD,
23BE,
2427,
0152,
2458,
24BE,
24BD,
24BC,
24BB,
24BA,
24B9,
24B8,
243F,
243E,
243D,
243C,
23AB,
23AD:
Replace
processor
M03
(see
–
For
all
other
feature
codes,
use
Table
6.
Processor
type
numbers
for
Models
270
and
820
(See
page
)
in
symbolic
FRU
to
determine
the
processor
type
to
be
replaced.
3.
Is
the
SRC
1xxx
CE1A?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Power
regulator
R03
on
FC
5077
expansion
I/O
tower
is
the
failing
item
(see
for
part
number).
This
ends
the
procedure.
4.
Is
the
SRC
1xxx
6018,
6118,
6518,
6818,
6918,
601A,
or
CE18?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Power
regulator
1,
2,
or
3
is
the
failing
item.
Perform
″
SPCN-PIP1
″
in
manual
on
the
V5R1
Supplemental
Manuals
web
site
to
determine
the
failing
item.
The
following
list
shows
the
possible
failing
items
(see
for
part
numbers):
–
Expansion
I/O
tower
(FC
5077)
–
System
unit
expansion
(FC
507x)
–
Storage
expansion
tower
(FC
508x)
This
ends
the
procedure.
5.
Is
the
SRC
1xxx
6218,
6318,
631A,
6618,
6718,
671A,
or
6A18?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Power
regulator
1
is
the
failing
item.
Perform
″
SPCN-PIP1
″
in
manual
on
the
V5R1
Supplemental
Manuals
web
site
to
determine
the
failing
item.
The
following
list
shows
the
possible
failing
items
(see
for
part
numbers):
–
Expansion
I/O
tower
(FC
5077)
–
System
unit
expansion
(FC
507x)
426
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation