This
ends
the
procedure.
12.
Is
the
SRC
1xxx
2330
or
2331?
v
No
:
Continue
with
the
next
step.
v
Yes
:
The
failing
item
is
power
supply
1
on
a
base
expansion
unit:
–
FC
5033
-
part
21H9364
–
FC
5034
(as
installed)
-
part
21H9364
or
44H7779
–
FC
5035
-
part
44H7779
Note:
FC
5035
may
contain
up
to
4
power
supplies.
The
reference
code
that
sent
you
here
refers
to
the
power
supply
on
the
base
expansion
unit.
See
the
Locations
and
Addresses
section
in
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
This
ends
the
procedure.
13.
Is
the
SRC
1xxx
2213?
v
No
:
Continue
with
the
next
step.
v
Yes
:
See
the
next
failing
item.
This
ends
the
procedure.
14.
Is
the
SRC
1xxx
2210?
v
No
:
Go
to
This
ends
the
procedure.
v
Yes
:
The
failing
item
is
power
supply
1
on
the
base
expansion
unit,
or
power
supply
2
on
the
internal
expansion
unit
of
an
FC
5035
expansion:
–
FC
5033
-
part
21H9364
–
FC
5034
(as
installed)
-
part
21H9364
or
44H7779
–
FC
5035
(power
supply
2)
-
part
44H7779
Note:
See
the
Locations
and
Addresses
section
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
This
ends
the
procedure.
QSYSOPR
For
use
by
authorized
service
providers.
For
more
information,
look
in
the
System
Operator
message
queue
for
a
message
with
the
same
date
and
time.
Perform
any
actions
defined
in
the
message.
REDH
For
use
by
authorized
service
providers.
The
processor
has
received
a
memory
error,
however,
analysis
has
determined
this
is
most
likely
due
to
a
previous
processor
error
than
a
memory
failure.
Perform
the
following:
1.
Look
in
the
Service
Action
Log
for
a
processor
error
(B4xx)
occurring
prior
to
this
B4xx
xEBF
error
and
replace
any
FRUs
associated
with
that
error.
Analyze
hardware
problems
443