If
this
does
not
correct
the
problem,
replace
the
cable.
Perform
to
determine
the
frame
ID
and
HSL
port
label
of
the
other
end
of
the
cable
you
will
be
exchanging
(if
you
do
not
already
know).
If
the
problem
is
corrected,
then
This
ends
the
procedure
.
If
replacing
the
cable
does
not
correct
the
problem,
continue
with
replacing
the
failing
end
FRUs.
Replace
the
link’s
failing
end
point
FRUs:
Use
the
following
table
to
determine
the
End
Point
FRUs
on
the
″
From
Frame
ID
″
port.
Replace
the
FRUs
one
at
a
time.
Table
3.
End
point
FRUs
Frame
type
End
point
FRUs
Models
270,
800,
and
810
v
For
frame
ID
0001
and
the
port
number
indicator
in
word
5
is
0001:
The
port
identified
is
a
connection
from
the
embedded
HSL
I/O
Bridge
in
the
system
unit
to
the
external
HSL
Port
″
A0
″
.
Exchange
the
HSL
I/O
Bridge
in
the
system
unit
using
symbolic
FRU
Model
820
v
For
frame
ID
0000,
with
port
number
indicator
(in
word
5)
0000:
The
port
identified
is
an
internal
connection
on
the
Network
Interface
Controller
(NIC).
Exchange
the
NIC
using
symbolic
FRU
v
For
frame
ID
0001,
with
port
number
indicator
(in
word
5)
0000:
The
port
identified
is
an
internal
connection
on
the
embedded
HSL
I/O
bridge.
Exchange
the
HSL
I/O
bridge
using
symbolic
FRU
Model
825
The
HSL
I/O
bridge
card,
in
position
C09
for
failed
ports
A0
or
A1,
C08
for
failed
ports
B0
or
B1
-
not
applicable
for
failed
ports
C0
and
C1.
The
System
unit
backplane,
in
position
CB1
for
failed
ports
A0,
A1,
B0,
or
B1
-
not
applicable
for
failed
ports
C0
and
C1.
The
System
unit
backplane
extender,
in
position
MB1
for
failed
ports
C0
and
C1
-
not
applicable
for
failed
ports
A0,
A1,
B0,
and
B1.
Models
830/SB2
v
For
loop
number
256
decimal
(01000
hexadecimal),
on
frame
ID
0000,
with
the
port
number
indicator
in
word
5
is
0000:
The
port
identified
is
the
internal
HSL
port
on
the
NIC
card
that
is
connected
to
the
FC
9074
Base
I/O
Tower
with
an
internal
ribbon
cable.
Exchange
the
internal
ribbon
cable
using
the
service
information
associated
with
FRU
name
HSL
Ribbon
Cable
(see
Note:
Before
exchanging
the
cable,
if
you
discover
that
the
ribbon
cable
is
not
securely
connected
to
the
NIC,
then
you
have
the
option
of
reseating
the
ribbon
cable
without
exchanging
it.
v
For
loop
number
256
decimal
(01000
hexadecimal),
on
frame
ID
0001,
with
the
port
number
indicator
in
word
5
is
0000:
The
port
identified
is
the
internal
HSL
port
on
the
FC
9074
Base
I/O
Tower’s
HSL
I/O
bridge
card
that
is
connected
to
the
NIC
with
an
internal
ribbon
cable.
Exchange
the
internal
ribbon
cable
using
the
service
information
associated
with
FRU
name
HSL
Ribbon
Cable
(see
Note:
Before
exchanging
the
cable,
if
you
discover
that
the
ribbon
cable
is
not
securely
connected
to
the
NIC
then
you
have
the
option
of
reseating
the
ribbon
cable
without
exchanging
it.
Models
840/SB3
-
Frame
0000
The
Network
Interface
Card
(NIC)
Models
870
and
890
-
Frame
0000
The
Network
Interface
Card
(NIC).
The
location
will
be
given
in
the
table.
Analyze
hardware
problems
461