Frame
type
End
point
FRUs
Base
I/O
units
-
Frame
0001
and
any
I/O
tower
The
HSL
I/O
bridge
card
If
replacing
the
End
Point
FRUs
for
the
″
From
Frame
ID
″
port
did
not
clear
up
the
error,
use
the
table
above
to
replace
the
End
Point
FRUs
at
the
other
end
of
the
cable.
Perform
to
determine
the
frame
ID
and
HSL
port
label
of
the
other
end
of
the
cable
(if
you
do
not
already
know).
This
ends
the
procedure.
SLOTERR
For
use
by
authorized
service
providers.
SLOTERR:
card
slot
control
hardware
detected
an
error.
The
multi-adapter
bridge
detected
a
problem
with
a
card
location
that
it
controls.
The
problem
is
in
the
controls
for
the
card
slot.
The
card
location
may
or
may
not
have
an
installed
card.
If
there
is
a
card
installed
in
that
location,
it
may
be
the
source
of
the
problem.
Note:
If
there
is
a
Linux
partition
in
the
system,
any
IOPs
plugged
into
slots
owned
by
a
Linux
partition
will
not
power
on.
This
error
will
be
logged.
Correct
the
situation
by
removing
the
IOP
cards.
1.
Is
there
a
single
card
position
listed
in
the
SAL
for
this
failing
item?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
step
5
(See
page
2.
Is
there
a
range
of
card
positions
(PCI
Bridge
Set)
listed
in
the
SAL
for
this
failing
item?
v
No
:
Continue
with
the
next
step.
v
Yes
:
LIC
could
not
identify
the
slot
with
the
error.
Perform
to
determine
the
card
position
with
the
failure.
This
ends
the
procedure.
3.
Record
the
Direct
Select
Address
(DSA)
which
is
word
7
of
the
SRC
from
the
SAL
display.
4.
Examine
the
muti-adapter
bridge
function
number
in
the
DSA.
See
in
the
Bus
PIP
Overview
page.
Is
the
multi-adapter
bridge
function
number
less
than
or
equal
to
7?
v
Yes
:
Go
to
Return
here
after
locating
the
card.
v
No
:
LIC
could
not
identify
the
slot
with
the
error.
Perform
to
determine
the
card
position
with
the
failure.
This
ends
the
procedure.
5.
Does
the
SRC
that
sent
you
here
appear
more
than
once,
OR
does
any
other
SRC
with
this
symbolic
FRU
appear
from
the
same
IPL
AND
against
the
same
resource?
v
Yes
:
The
failure
is
at
the
multi-adapter
bridge.
Do
not
use
this
symbolic
FRU.
Go
to
the
next
failing
item
in
the
list.
This
ends
the
procedure.
v
No
:
Locate
the
message
in
the
following
table
to
determine
the
problem
and
the
corrective
action.
462
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation