Instructions
for
Model
270
and
820
1.
Is
the
SRC
1xx
8401?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Exchange
the
control
panel.
See
symbolic
FRU
for
the
correct
part.
This
ends
the
procedure.
2.
Is
the
SRC
1xxx
8402?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Prior
to
exchanging
any
parts,
verify
that
the
processors
are
installed.
If
you
are
in
test
mode
and
have
removed
all
of
the
processors,
disregard
this
SRC.
Otherwise,
correct
the
processors.
If
the
processors
are
installed
correctly,
then
exchange
the
control
panel.
See
symbolic
FRU
for
the
correct
part.
This
ends
the
procedure.
3.
Is
the
SRC
1xxx
8403?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Check
that
processor
1
is
connected
and
seated
properly
if
pluggable
and
then
exchange
processor
1.
See
symbolic
FRU
for
the
correct
part,
and
for
location
information.
This
ends
the
procedure.
4.
Is
the
SRC
1xxx
8404?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Exchange
the
following
parts
one
at
a
time:
–
Model
270
-
FC
2248,
FC
2250,
FC
2252,
FC
2422,
FC
2423,
FC
2431,
FC
2432
and
FC
2452
-
System
backplane.
See
symbolic
FRU
for
the
correct
part.
–
Models
270
-
FC
2252,
FC
2422,
FC
2423,
FC
2431,
FC
2432
and
FC
2452,
and
Model
820
-
Processor
2.
See
symbolic
FRU
for
the
correct
part,
and
for
location
information.
This
ends
the
procedure.
5.
Is
the
SRC
1xxx
8405?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Exchange
Processor
3.
See
symbolic
FRU
for
the
correct
part,
and
for
location
information.
If
there
is
not
a
Processor
3,
see
the
next
FRU.
This
ends
the
procedure.
6.
Is
the
SRC
1xxx
8406?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Exchange
Processor
4.
See
symbolic
FRU
for
the
correct
part,
and
for
location
information.
If
there
is
not
a
Processor
4,
see
the
next
FRU.
This
ends
the
procedure.
7.
Is
the
SRC
1xxx
8409?
v
No
:
Continue
with
the
next
step.
v
Yes
:
No
processors
are
installed.
If
you
are
in
test
mode
and
have
removed
all
the
processors,
disregard
this
SRC.
Otherwise,
correct
the
processors.
If
the
processors
are
installed
correctly,
exchange
all
processors.
See
symbolic
FRU
for
the
correct
part,
and
for
location
information.
This
ends
the
procedure.