v
Yes
:
Go
to
step
15
(See
page
.
DANGER
Dangerous
voltage
being
measured.
(RSFTD005)
v
No
:
Use
a
multimeter
to
measure
the
ac
voltage
at
the
customer’s
ac
power
outlet.
Is
the
ac
voltage
from
200
V
ac
to
240
V
ac
or
from
100
V
ac
to
127
V
ac?
–
No
:
Inform
the
customer
that
the
ac
voltage
at
the
power
outlet
is
not
correct.
This
ends
the
procedure.
–
Yes
:
Continue
with
the
next
step.
5.
Is
the
mainline
ac
power
cable
from
the
AC
module,
battery
charger,
power
supply
or
power
distribution
unit
to
the
customer’s
ac
power
outlet
connected
and
seated
correctly
at
both
ends?
v
No
:
Connect
the
mainline
ac
power
cable
correctly
at
both
ends.
This
ends
the
procedure.
v
Yes
:
Continue
with
the
next
step.
6.
DANGER
Dangerous
voltage
being
measured.
(RSFTD005)
Perform
the
following:
a.
Disconnect
the
mainline
ac
power
cable
from
the
AC
module,
battery
charger,
power
supply
or
power
distribution
unit.
b.
Use
a
multimeter
to
measure
the
ac
voltage
at
the
AC
module,
battery
charger,
power
supply
or
power
distribution
unit
end
of
the
mainline
ac
power
cable.
Is
the
ac
voltage
from
200
V
ac
to
240
V
ac
or
from
100
V
ac
to
127
V
ac?
v
Yes
:
Go
to
step
9
(See
page
.
v
No
:
Continue
with
the
next
step.
7.
Are
you
working
on
a
power
distribution
unit
with
tripped
breakers?
v
Yes
:
Reset
the
tripped
power
distribution
breaker
and
go
to
the
power
problem
procedure
for
the
unit
that
is
connected
to
the
tripped
breaker.
v
No
:
Continue
with
the
next
step.
8.
Exchange
the
mainline
ac
power
cable
or
power
distribution
unit
(as
installed).
This
ends
the
procedure.
9.
Does
the
unit
you
are
working
on
have
ac
power
jumper
cables
installed?
(ac
power
jumper
cables
connect
from
the
AC
module,
battery
charger
unit,
or
the
power
distribution
unit
to
the
power
supplies.)
v
No
:
Go
to
step
14
(See
page
.
v
Yes
:
Continue
with
the
next
step.
10.
Are
the
ac
power
jumper
cables
from
the
AC
module,
battery
charger
unit,
or
power
distribution
unit
to
the
power
supplies
connected
and
seated
correctly
at
both
ends?
v
No
:
Connect
the
ac
power
jumper
cables
correctly
at
both
ends.
This
ends
the
procedure.
v
Yes
:
Continue
with
the
next
step.
11.
DANGER
Dangerous
voltage
being
measured.
(RSFTD005)
Perform
the
following:
a.
Disconnect
the
ac
power
jumper
cables
from
the
battery
charger
unit
AC
module
or
power
distribution
unit.
Analyze
hardware
problems
57