e.
Go
to
HSM
in
the
Primary
partition,
and
select
Logical
hardware
resources
—>
System
bus
resources
—>
Display
detail
for
each
system
bus
on
the
Logical
Hardware
Resources
on
System
Bus
display
until
you
find
the
bus
with
the
same
bus
number
you
recorded
for
the
IOP.
f.
For
the
system
bus
that
you
found,
select
Associated
packaging
resource(s)
.
g.
Record
the
frame
ID
in
the
″
Frame
ID
″
column.
4.
Record
the
frame
type/feature
by
using
the
frame
ID
and
system
configuration
listing
OR
locate
the
frame
with
that
ID
and
record
the
frame
type/feature.
5.
Choose
one
of
the
following
options:
v
For
Models
800,
810,
825,
870,
and
890:
Continue
with
the
next
step.
v
For
Models
270,
820,
830,
840,
SB2,
and
SB3:
Is
the
bus
number
that
you
recorded
for
the
IOP
between
4
and
23
(in
decimal)?
–
Yes:
Perform
Bus
PIP
CNSL01
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
This
ends
the
procedure.
–
No:
Continue
with
the
next
step.
6.
Determine
and
record
the
card
location
of
the
IOP
by
going
to
the
and
locating
the
card
position
table
for
the
frame
type/feature
you
recorded
in
the
previous
step.
Then,
continue
with
the
next
step.
7.
Exchange
the
IOP
in
that
card
position
by
performing
the
following
steps:
a.
Refer
to
and
select
the
frame
type/feature
that
you
recorded.
b.
Go
to
the
FRU
locations
and
failing
items
table
for
the
frame
type/feature
that
you
recorded.
c.
Locate
the
card
position
in
the
FRU
locations
and
failing
items
table
and
use
the
remove
and
replace
procedure
identified
for
that
card
location.
d.
Power
on
the
secondary
partition.
This
ends
the
procedure.
8.
The
problem
is
in
the
Primary
partition
of
a
system
with
one
or
more
partitions.
Choose
from
the
following
options:
v
For
Models
270
and
820:
The
console
IOP
is
embedded
in
the
system
unit
backplane.
Exchange
the
system
unit
backplane
using
symbolic
FRU
Then,
power
on
the
system.
This
ends
the
procedure.
v
For
Models
800
and
810
:
The
console
IOP
is
embedded
in
the
system
unit
backplane.
Exchange
the
system
unit
backplane
using
symbolic
FRU
Then,
power
on
the
system.
This
ends
the
procedure.
v
For
Model
825
:
The
console
IOP
is
in
slot
C09.
Exchange
the
Network
Interface
Controller
(NIC)
Card.
See
for
location
information,
diagrams,
and
links
to
remove
and
replace
procedures.
This
ends
the
procedure.
v
For
Models
830,
840,
SB2,
and
SB3:
The
console
IOP
is
in
the
base
I/O
tower
for
the
system
unit.
Exchange
the
IOP
in
card
position
C01.
–
For
Model
830
systems,
the
IOP
is
in
card
location
C01
of
the
FC
9074
base
I/O
tower
in
frame
1
of
the
system
unit.
To
see
where
the
IOP
is
located
in
the
system
unit,
and
determine
the
CCIN
and
remove
and
replace
procedure
for
the
IOP,
locate
card
position
C01
in
the
FRU
locations
and
failing
components
table
in
power
on
the
system.
This
ends
the
procedure.
–
For
Model
840
systems,
the
IOP
is
in
card
location
C01
of
the
FC
9079
base
I/O
tower
in
frame
1
of
the
system
unit
towers.
To
see
where
the
IOP
is
located
in
the
base
I/O
tower,
and
to
determine
the
CCIN
and
remove
and
replace
procedure
for
the
IOP,
locate
card
position
C01
in
78
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation