v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 8850,” on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code
Description
Action
3-1-1
Timer tick interrupt failed.
(Trained service technician only) Replace the
system board assembly.
3-1-2
Interval timer channel 2 failed.
(Trained service technician only) Replace the
system board assembly.
3-1-3
RAM test failed above address 0FFFFh.
1. Reseat the DIMMs.
2. Replace the following components one at a
time, in the order shown, restarting the
server each time.
a. DIMMs
b. (Trained service technician only) System
board assembly
3-1-4
Time-of-day clock failed.
1. Reseat the battery.
2. Replace the following components one at a
time, in the order shown, restarting the
server each time.
a. Battery
b. (Trained service technician only) System
board assembly
3-2-1
Serial port failed.
(Trained service technician only) Replace the
system board assembly.
3-2-3
Math coprocessor test failed
1. (Trained service technician only) Reseat the
microprocessor.
2. Replace the following components one at a
time, in the order shown, restarting the
server each time.
a. (Trained service technician only)
Microprocessor
b. (Trained service technician only) System
board assembly
3-2-4
Failure comparing CMOS memory size
against actual
1. Reseat the following components:
a. DIMMs
b. Battery
2. Replace the following components one at a
time, in the order shown, restarting the
server each time.
a. DIMMs
b. (Trained service technician only) System
board assembly
c. Battery
Chapter 2. Diagnostics
13
Summary of Contents for LS20 - BladeCenter - 8850
Page 1: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 2: ......
Page 3: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 14: ...xii AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 72: ...58 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 104: ...90 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 114: ...100 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 115: ......
Page 116: ...Part Number 49Y0167 Printed in USA 1P P N 49Y0167...