POST error codes
The following table describes the POST error codes and suggested actions to
correct the detected problems.
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 8850,” on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
161
Real-time clock battery error.
1. Run the Configuration/Setup Utility program.
2. Reseat the battery.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. Battery
b. (Trained service technician only) System
board assembly
162
Device configuration error.
1. Run the Configuration/Setup Utility program,
select
Load Default Settings
, and save the
settings.
2. Reseat the following components:
a. Battery
b. Failing device
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. Battery
b. Failing device
c. (Trained service technician only) System
board assembly
163
Real-time clock error.
1. Run the Configuration/Setup Utility program,
select
Load Default Settings
, make sure that the
date and time are correct, and save the settings.
2. Reseat the battery.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. Battery
b. (Trained service technician only) System
board assembly
184
Power-on password damaged.
1. Run the Configuration/Setup Utility program,
select
Load Default Settings
, and save the
settings.
2. (Trained service technician only) Replace the
system board assembly.
189
An attempt was made to access the server
with invalid passwords.
Restart the server, run the Configuration/Setup Utility
program and change the power-on password.
Chapter 2. Diagnostics
19
Summary of Contents for LS20 - BladeCenter - 8850
Page 1: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 2: ......
Page 3: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 14: ...xii AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 72: ...58 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 104: ...90 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 114: ...100 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 115: ......
Page 116: ...Part Number 49Y0167 Printed in USA 1P P N 49Y0167...