v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 8850,” on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
201-xxx-PBD
Test failed.
v
P = CPU Number [1 - 4].
v
B = Failing Bank/Pair number.
v
D = Failing dimm number within Failing
CPU # P.
v
D = 9 = Both dimms in the failing
bank/pair of dimms.
1. Reseat the failing DIMM, then; run the memory
diagnostic test.
2. Replace the failing DIMM(s), then; run the
memory diagnostic test.
3. (Trained service technician only) System board
assembly.
202-xxx-001
Failed system cache test.
1. Reseat microprocessor 1.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only) System
board assembly
202-xxx-002
Failed system cache test.
1. Reseat microprocessor 2.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 2
b. (Trained service technician only) System
board assembly
217-198--xxx
Could not establish drive parameters.
1. Reseat hard disk drive x.
2. Flash the BIOS code.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. Hard disk drive x
b. (Trained service technician only) System
board assembly
217-xxx-000
Failed hard disk drive test.
Note:
If RAID is configured, the fixed disk
number refers to the RAID logical drive.
1. Reseat hard disk drive 1.
2. Replace hard disk drive 1.
217-xxx-001
Failed hard disk drive test.
Note:
If RAID is configured, the fixed disk
number refers to the RAID logical drive.
1. Reseat hard disk drive 2.
2. Replace hard disk drive 2.
405-xxx-000
Failed Ethernet test on controller on the
system board.
1. Make sure that Ethernet is not disabled in the
Configuration/Setup Utility program.
2. Update the Ethernet firmware (see “Configuring
the Gigabit Ethernet controllers” on page 88).
3. (Trained service technician only) Replace the
system board assembly.
48
AMD Opteron LS20 Type 8850 for IBM BladeCenter: Problem Determination and Service Guide
Summary of Contents for LS20 - BladeCenter - 8850
Page 1: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 2: ......
Page 3: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 14: ...xii AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 72: ...58 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 104: ...90 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 114: ...100 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 115: ......
Page 116: ...Part Number 49Y0167 Printed in USA 1P P N 49Y0167...