To install a concurrent KVM feature card, complete the following steps:
1.
Touch the static-protective package that contains the expansion card to any
unpainted
metal surface on the BladeCenter unit or any
unpainted
metal surface
on any other grounded rack component; then, remove the concurrent KVM
feature card from the package.
2.
Locate the concurrent-KVM connector and orient the concurrent KVM feature
card over it.
3.
Slide the right side of the card (the side of the card that is away from the
concurrent-KVM connector) between the two tabs at the right side of the
expansion card bracket; then, gently pivot the card into the connector.
Note:
For device-driver and configuration information to complete the
installation of the concurrent KVM feature card, see the documentation that
comes with the card.
4.
If you removed any of the following expansion cards while you removed the
concurrent KVM card, reinstall them:
v
Small-form-factor card (see “Installing a small-form-factor expansion card”
on page 44).
v
Combination-form-factor card (see “Removing a combination-form-factor
expansion card” on page 42)
v
High-speed expansion card (see “Removing a high-speed expansion card” on
page 41)
5.
Install the MPE unit or expansion unit, if you removed one while you removed
the concurrent KVM card (see “Installing an expansion unit” on page 32).
6.
Install the blade server cover (see “Installing the blade server cover” on page
30).
7.
Install the blade server into the BladeCenter unit (see “Installing the blade
server in a BladeCenter unit” on page 28).
Removing a USB flash drive
The following illustration shows how to remove an embedded USB flash drive
from the blade server system board.
52
BladeCenter LS22 Type 7901 and LS42 Type 7902: Problem Determination and Service Guide
Summary of Contents for LS42 - BladeCenter - 7902
Page 1: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Page 12: ...x BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Page 76: ...64 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Page 192: ...180 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Page 193: ......
Page 194: ...Part Number 49Y0107 Printed in USA 1P P N 49Y0107...