The
following
illustration
shows
how
to
remove
a
CFFh
expansion
card
from
the
blade
server;
removing
a
combination-form-factor
expansion
card
from
a
MPE
unit
is
similar.
a.
Locate
the
CFFh
card
in
the
blade-expansion
connector
(see
“Blade
server
connectors”
on
page
14).
b.
Pull
up
the
release
lever
on
the
CFFh
card
until
the
card
disconnects
from
the
blade-expansion
connector.
c.
Pull
the
card
toward
the
front
of
the
blade
server
to
remove
it
from
the
card
retainer
brackets.
6.
Remove
the
CFFv
card:
The
following
illustration
shows
how
to
remove
a
CFFv
expansion
card
from
the
blade
server;
removing
a
combination-form-factor
expansion
card
from
a
MPE
unit
is
similar.
a.
Locate
the
CFFv
card
in
the
I/O-expansion
card
connector
(see
“Blade
server
connectors”
on
page
14).
b.
Pull
up
on
the
CFFv
card
to
remove
it
from
the
expansion
connector;
then,
lift
the
card
out
of
the
blade
server.
7.
If
you
have
other
devices
to
install
or
remove,
do
so
now;
otherwise,
go
to
“Completing
the
installation”
on
page
46.
Chapter
3.
Installing
optional
devices
37
Summary of Contents for LS42 - BladeCenter - 7902
Page 1: ......
Page 2: ......
Page 3: ...BladeCenter LS22 and LS42 Type 7901 and 7902 Installation and User s Guide...
Page 26: ...16 BladeCenter LS22 and LS42 Type 7901 and 7902 Installation and User s Guide...
Page 88: ...78 BladeCenter LS22 and LS42 Type 7901 and 7902 Installation and User s Guide...
Page 89: ......
Page 90: ...Part Number 44R5057 Printed in USA 1P P N 44R5057...