Configuration Data
The configuration data descriptions follow. Each separate element contains 32
bytes.
Table
4-30 (Page 1 of 5). Internal Disk Configuration Data
Byte(s)(1)
Description
Bytes 0-31:
(2) NED1; contains the NED for the Volume
0
(0)
Flags
Bit Description
0-1
Field Identifier; set to B
'
11
'
to indicate a NED
2
Token Indicator; set to B
'
0
'
3-4
Serial-number Indicator; set to B
'
00
'
to indicate that this serial-number is
identical to the serial-number contained in the next NED that has a nonzero
serial-number indicator.
5
Reconfiguration NED; set to B
'
0
'
.
6
Emulation NED; set to B
'
0
'
7
Reserved; set to B
'
0
'
1
(1)
Type; set to X
'
01
'
to indicate I/O device
2
(2)
Class; set to X
'
01
'
to indicate DASD
3
(3)
Level
Bit Description
0-6
Reserved; set to zeros
7
Level; set to B
'
0
'
to indicate that this NED has a hierarchical relationship to
the next NED in this configuration record
4-9
(4-9)
Type Number (EBCDIC); set to the Internal Disk subsystem type number which is
'
IDSK
'
10-12
(10-12)
Model Number (EBCDIC); set to the Internal Disk subsystem model number which is
'
002
'
13-15
(13-15)
Manufacturer (EBCDIC); set to
'
IBM
'
16-17
(16-17)
Manufacturing Plant Code(3) (EBCDIC)
18-21
(18-21)
Sequence Number High (EBCDIC); this portion of the sequence number field is used
to hold the control unit number. These characters are in EBCDIC notation,
representing four hexadecimal characters. This allows for up to X
'
FFFF
'
control
units.
22-29
(22-29)
Sequence Number Low (EBCDIC); this portion of the sequence number field is used
to hold the 5-character box sequence number(4) for the Internal Disk subsystem.
Included in this field are three leading zeros. All eight characters are in EBCDIC
notation.
30-31
(30-31)
Tag; this field is used to uniquely identify the Logical Volume within the Internal Disk
subsystem.
Bit Description
0-3
Reserved, set to zeros
4-7
Control Unit Logical Address (CULA)
8-15
Unit Address; this is the address by which this volume is known to the system
Bytes 32-63:
NED2; contains the NED for the RAID Array
4-112
Internal Disk Subsystem Reference Guide
Summary of Contents for Multiprise 3000
Page 2: ......
Page 3: ...S 390 IBM Internal Disk Subsystem Reference Guide SA22 1025 00 ...
Page 32: ...2 12 Internal Disk Subsystem Reference Guide ...
Page 38: ...3 6 Internal Disk Subsystem Reference Guide ...
Page 182: ...4 144 Internal Disk Subsystem Reference Guide ...
Page 198: ...5 16 Internal Disk Subsystem Reference Guide ...
Page 214: ...6 16 Internal Disk Subsystem Reference Guide ...
Page 234: ...A 10 Internal Disk Subsystem Reference Guide ...
Page 238: ...B 4 Internal Disk Subsystem Reference Guide ...
Page 243: ...4 lease the Code or any copy of it Appendix C Warranties C 5 ...
Page 244: ...C 6 Internal Disk Subsystem Reference Guide ...
Page 248: ...D 4 Internal Disk Subsystem Reference Guide ...
Page 254: ...X 6 Internal Disk Subsystem Reference Guide ...
Page 263: ......