Microcode detected data discrepancy, message 3
Intervention required, message 9, due to:
1. Not physically attached to Internal Disk
2. Not available for use because the drive motor is off or is powering on.
3. The HDD has been disabled via the Service Element.
4. The SSA Adapter Card has been removed for service.
Device fails to respond and predictive failure analysis are physical device errors.
They are presented with Equipment Check (byte 0, bit 3) set equal to b‘1’and
Permanent Error (byte 1, bit 0) set equal to b‘0’. Included with the physical
Included with the physical device errors are data discrepancies detected by the
Internal Disk microcode. They are presented with Equipment Check (byte 0, bit 3)
set equal to b‘1’and Permanent Error (byte 1, bit 0) set equal to b‘0’. Message 3
is used to uniquely identify these errors. An example is a media error on both
HDDs of a mirrored pair while doing resynchronization. Also, Internal Disk uses this
Unit Check when a record sequence number mismatch occurs on only one HDD.
The operation terminates, but when the track is reaccessed, internal recovery
procedures are used to resync the HDDs and correct the sequence number
mismatch.
Intervention required is indicated by byte zero, bit 1 set to b'1' and Permanent Error
(byte 1, bit 0) set equal to b'0'.
Sense Bytes 8 through 23 for Format 1
Format 1 sense bytes 8 through 23 contain the following:
Table
5-7. Sense Bytes 8–23 – Format 1
Bytes
Definition
8–15
Reserved, set to zeros.
16
Cylinder Address (1-128) if the logical volume is 3380-E. Otherwise, '00'x.
17
Cylinder Address (256 and 512) and head address if the logical volume is
3380-E. Otherwise, '00'x.
18–20
Reserved, set to zeros.
21
Low order byte of the SSID
22–23
Symptom code. See Format 1 Messages below.
Format 1 Messages
The following messages are for format 1:
5-12
Internal Disk Subsystem Reference Guide
Summary of Contents for Multiprise 3000
Page 2: ......
Page 3: ...S 390 IBM Internal Disk Subsystem Reference Guide SA22 1025 00 ...
Page 32: ...2 12 Internal Disk Subsystem Reference Guide ...
Page 38: ...3 6 Internal Disk Subsystem Reference Guide ...
Page 182: ...4 144 Internal Disk Subsystem Reference Guide ...
Page 198: ...5 16 Internal Disk Subsystem Reference Guide ...
Page 214: ...6 16 Internal Disk Subsystem Reference Guide ...
Page 234: ...A 10 Internal Disk Subsystem Reference Guide ...
Page 238: ...B 4 Internal Disk Subsystem Reference Guide ...
Page 243: ...4 lease the Code or any copy of it Appendix C Warranties C 5 ...
Page 244: ...C 6 Internal Disk Subsystem Reference Guide ...
Page 248: ...D 4 Internal Disk Subsystem Reference Guide ...
Page 254: ...X 6 Internal Disk Subsystem Reference Guide ...
Page 263: ......