Do not plug any cables in the ESH2/ESH4 or AT-FCX Output port of the last
unit. The storage expansion units are self-terminating.
Note:
The AT-FCX and ESH2/ESH4 modules are self-terminating. The
ESH2/ESH4 does not have a terminate switch.
4.
Repeat Step 1 on page 13 through Step 3 on page 13 for the partner node.
5.
Cable the dual-port expansion adapter Port b, of the local node, to the partner
storage expansion unit 1 Channel B ESH2/ESH4 or AT-FCX Input port.
6.
Cable the local storage expansion unit 1 Channel B ESH2/ESH4 or AT-FCX
Output port to the local storage expansion unit 2 Channel B ESH2/ESH4 or
AT-FCX Input port.
7.
Repeat Step 6, connecting Channel B output to input, for any remaining storage
expansion units in the disk pool.
8.
Repeat Step 5 through Step 7 for the partner node.
Connecting a gateway to external storage
You must use fiber-optic cables to connect a gateway to external storage on a Fibre
Channel SAN.
See the
Gateway Interoperability Matrix
at the following web page for supported
third-party storage for your N7000 series system.
www.ibm.com/systems/storage/network/interophome.html
Refer to the documentation for your external storage for additional information.
Connecting your N7000 series system to a third-party device
You can connect third-party devices to your N7000 series system through an
optical Fibre Channel interface using any Fibre Channel port on the back of the
chassis.
The N7000 series systems only support third-party devices with an optical Fibre
Channel interface. For supported devices for your system, see the
Interoperability
Matrix
on the IBM N series support website, which is accessed and navigated as
described in “Websites” on page xx.
Refer to the documentation that comes with the third-party device for connection
information.
Rules for connecting the third-party devices
Observe the following rules for connecting the third-party devices:
v
Use a fiber-optic cable that is:
– Appropriate to the Fibre Channel connection on your system
– Of an approved length for the third-party device
Note:
See the documentation for the third-party device.
v
An unsupported tape backup device might cause the system to halt. To verify
support for your third-party device, check the
Interoperability Matrix
on the IBM
N series support website, which is accessed and navigated as described in
“Websites” on page xx.
14
IBM System Storage: N7000 Series Hardware and Service Guide
Summary of Contents for N7700
Page 2: ......
Page 12: ...x IBM System Storage N7000 Series Hardware and Service Guide ...
Page 18: ...xvi IBM System Storage N7000 Series Hardware and Service Guide ...
Page 20: ...xviii IBM System Storage N7000 Series Hardware and Service Guide ...
Page 42: ...16 IBM System Storage N7000 Series Hardware and Service Guide ...
Page 46: ...20 IBM System Storage N7000 Series Hardware and Service Guide ...
Page 54: ...28 IBM System Storage N7000 Series Hardware and Service Guide ...
Page 162: ...136 IBM System Storage N7000 Series Hardware and Service Guide ...
Page 164: ...138 IBM System Storage N7000 Series Hardware and Service Guide ...
Page 168: ...142 IBM System Storage N7000 Series Hardware and Service Guide ...
Page 181: ......
Page 182: ... Printed in USA GC26 7953 13 ...