Ethernet Subsystem Error Messages
Notes
1. The following error messages may be displayed if
"Network" is selected in the startup sequence of
the Configuration/Setup Utility program program.
2. The following error messages are available only
with the integrated Ethernet subsystem. These
error messages are not available when RPL
(remote program load) or DHCP (dynamic host
configuration protocol) is used through optional
network adapters.
RPL-Related Error Messages:
If a failure
condition occurs after the Ethernet controller is initialized,
an error message appears on the screen.
The two most common error messages are:
RPL-ROM-ERR:
1ð5
The integrated Ethernet failed the loopback test.
RPL-ROM-ERR:
1ð7
Media test failed; check the cable.
Error 105 indicates that a power-on diagnostic test
performed by the Ethernet module did not execute
correctly. If this error message appears, you must have
the server serviced. Error 107 indicates that the cable
from the LAN is not securely connected to the Ethernet
port on your computer. Check the cable to ensure that it is
properly connected.
The following list contains other error codes that might
occur, followed by a description of the error code.
Note
An
x value that follows an error code represents any
alphanumeric character.
Table 2 (Page 1 of 4). Ethernet Controller
Messages
Error Code
Description
RPL-ROM-ERR: 100
The integrated Ethernet controller cannot be found.
RPL-ROM-ERR: 101
The integrated Ethernet controller was unable to initialize.
RPL-ROM-ERR: 102
The integrated Ethernet controller could not be reset
controller.
IBM Netfinity 3500 - Type 8644
35
Summary of Contents for Netfinity 3500 Series
Page 2: ......
Page 6: ...iv IBM Netfinity Servers HMM...
Page 8: ...vi IBM Netfinity Servers HMM...
Page 100: ...Assignments 92 IBM Netfinity Servers HMM...
Page 151: ......
Page 152: ...IBM Part Number 10L9833 Printed in U S A S 5L 19 8 1...