Setting the Ethernet Controller Operation Mode Switch
When you want to change the Ethernet controller operation mode
from Normal to MAC Disabled, you must change the setting of
configuration switch 6.
Before you begin:
Read “Electrical Safety” on page 54 and “Handling
Static-Sensitive Devices” on page 55.
Turn off the server and all other connected devices.
Disconnect all external cables attached to the server; then,
remove the server cover (see “Preparing to Add Options” on
page 56).
1. Locate the configuration switches (also known as rocker
switches) on the system board. For more information, refer to
the label inside the server, or see “System Board Illustration” on
page 203.
2. To set the Ethernet controller operation mode to the appropriate
value, set switch 6 as shown in the following illustration. It
might be helpful to use the end of a small screwdriver to set the
switch.
Note: In the following illustration, MAC represents media
access control. This refers to the Ethernet controller
address.
Ethernet Normal Operation
Ethernet MAC Disabled
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
ON
ON
OFF
OFF
3. Move the switch to the ON position.
4. Make the required adjustments to the Ethernet controller
address.
5. Move the switch back to the OFF position.
Chapter 7. Server Records and Specifications
213
Summary of Contents for Netfinity 3500
Page 1: ...Netfinity 3500 User s Handbook...
Page 2: ......
Page 3: ...Netfinity 3500 User s Handbook IBM...
Page 8: ...vi Netfinity 3500 User s Handbook...
Page 14: ...Laser Compliance Statements xii Netfinity 3500 User s Handbook...
Page 32: ...Input Output Connectors 14 Netfinity 3500 User s Handbook...
Page 200: ...Replacing the Battery 182 Netfinity 3500 User s Handbook...
Page 210: ...Ordering Publications 192 Netfinity 3500 User s Handbook...
Page 250: ...Taiwan Class A Electronic Emission Statement 232 Netfinity 3500 User s Handbook...
Page 266: ...248 Netfinity 3500 User s Handbook...
Page 293: ......
Page 294: ...IBM Part Number 05L2067 Printed in U S A January 1998 5L2 67...