After an installation source directory has been created, use a response file and the
Netfinity Manager installation program command-line parameters. The Netfinity
Manager installation program supports the following command-line parameters:
/R:
drive+path+filename
Specifies the drive, path, and file name of the response file.
See the NETFBASE.RSP file (located in the directory in
which Netfinity Manager was installed) for an example of a
response file with comments on the included parameters.
/S:
drive+path
Specifies the drive and path to install
from. This is the
directory to which the files were copied.
/T:
drive
Specifies the drive to install
to. Default is the current
startup drive.
/TU:
drive+path
Specifies the drive and path of the CONFIG.SYS file to
update. The default is to change the CONFIG.SYS in the
root directory of the drive specified in the /T parameter (or
the startup drive). This parameter is ignored if the
ChangeConfig parameter in the response file is FALSE.
For example, the line:
NETFINST /R:NETFBASE.RSP /S:Y:\NETFIN
/T:C /TU:D:\
will install Netfinity Manager, using the options in the
response file NETFBASE.RSP, from the directory
Y:\NETFIN, to drive C: (the directory to which the files are
installed is taken from the response file), and will modify
the CONFIG.SYS file in the D:\ directory.
Note: For information on how to use a CID-enabled software distribution manager,
refer to the publications provided with the individual CID-enabled product.
Customized installation
Usually, not all users need to have access to all services. For security reasons,
user access can be restricted by creating a customized installation that will prevent
some services from being installed.
To create a customized installation, the INSTALL.INI file must be edited. For
example, when creating a customized Netfinity Manager for Windows 95 or NT
installation, edit the INSTALL.INI file that is found on Netfinity directory.
The INSTALL.INI file has three sections, separated by the line
[==]
The first section contains the installation configuration that can be selected during
installation. There can be no more than eight choices. Each choice takes up two
lines. The first line is the text that is displayed next to the installation configuration
radio button. The second line is a list of the options in the third section that will be
installed when this choice is selected for installation.
For example:
68
Netfinity
4000R User's Handbook
Summary of Contents for NETFINITY 4000R
Page 1: ...IBM IBM Netfinity 4000R User s Handbook...
Page 2: ......
Page 3: ...IBM IBM Netfinity 4000R User s Handbook...
Page 12: ...2 Netfinity 4000R User s Handbook...
Page 32: ...22 Netfinity 4000R User s Handbook...
Page 38: ...28 Netfinity 4000R User s Handbook...
Page 48: ...38 Netfinity 4000R User s Handbook...
Page 76: ...66 Netfinity 4000R User s Handbook...
Page 81: ...Section 3 Appendixes Copyright IBM Corp 1999 71...
Page 82: ...72 Netfinity 4000R User s Handbook...
Page 86: ...76 Netfinity 4000R User s Handbook...
Page 88: ...78 Netfinity 4000R User s Handbook...
Page 98: ...88 Netfinity 4000R User s Handbook...
Page 102: ...IBM Part Number 00N9106 Printed in U S A N91 6...