Before You Begin
Table 11. Netfinity 5000 Server Operating Specifications
Size
– Depth: 560 mm (22.05 in.)
– Height: 230 mm (9.06 in.)
– Width: 420 mm (16.54 in.)
Weight
Typical server as shipped: 39 kg
(85.8 lb)
Environment
Air temperature:
– Server on: 10° to 35° C
(50° to 95° F)
Altitude: 0 to 914 m (3000 ft.)
– Server on: 10° to 32° C
(50° to 90° F)
Altitude: 914 m (3000 ft.) to
2133 m (7000 ft.)
– Server off: 10° to 43° C
(50° to 110° F)
Maximum Altitude: 2133 m
(7000 ft.)
Humidity:
– Server on: 8% to 80%
– Server off: 8% to 80%
Maximum altitude: 2133 m
(7000 ft)
Electrical Input
Sine-wave input (50 to 60 Hz) is
required
Input voltage:
– Low range:
- Minimum:
90 V ac
- Maximum: 137 V ac
– High range:
- Minimum: 180 V ac
- Maximum: 265 V ac
– Input kilovolt-amperes (kVA)
approximately:
- Minimum configuration as
shipped: 0.08 kVA
- Maximum configuration:
0.52 kVA
Total Power Available for Drives
Nominal Operating Current allowed:
– +5 V dc line: 5.3 A
– +12 V dc line: 5.0 A
Heat Output
Approximate heat output in British
Thermal Units (Btu) per hour:
– Minimum configuration:
350 Btu (102 watts)
– Maximum configuration:
860 Btu (251 watts)
Acoustical Noise Emissions Values
Sound power, idling
– 6.2 bel for open bay system
(no hard disk drives installed)
– 6.3 bel for system with one
hard disk drive installed)
Sound power, operating
– 6.2 bel for open bay system
(no hard disk drives installed)
– 6.3 bel for system with one
hard disk drive installed)
Sound pressure, idling
– 47 dBa for open bay system
(no hard disk drives installed)
– 48 dBa for system with one
hard disk drive installed)
Sound pressure, operating
– 47 dBa for open bay system
(no hard disk drives installed)
– 48 dBa for system with one
hard disk drive installed)
Chapter 5. Installing a Server in a Rack Enclosure