Result
can be one of the following:
Passed:
This result occurs when the diagnostic
test completes without any errors.
Failed:
This result occurs when the diagnostic
test discovers an error.
User Aborted:
This result occurs when you stop
the diagnostic test before it is complete.
Not Applicable:
This result occurs when you
specify a diagnostic test for a device that is not
present.
Aborted:
This result occurs when the test could
not proceed because of the system
configuration.
Warning:
This result occurs when a possible
problem is reported during the diagnostic test,
such as when a device that is to be tested is not
installed.
Test Specific String
This is additional information that you can use to
analyze the problem.
Starting the diagnostic programs
You can press F1 while running the diagnostic programs to
obtain
Help
information. You also can press F1 from within
a help screen to obtain online documentation from which
you can select different categories. To exit
Help
and return
to where you left off, press Esc.
To start the diagnostic programs:
1. Turn on the server and watch the screen.
Note:
To run the diagnostic programs, you must start
the server with the highest level password that
is set. That is, if an administrator password is
set, you must enter the administrator password,
not the power-on password, to run the
diagnostic programs.
2. When the message
F2 for Diagnostics
appears,
press F2.
3. Type in the appropriate password; then, press Enter.
4. Select either
Extended
or
Basic
from the top of the
screen.
5. When the Diagnostic Programs screen appears, select
the test you want to run from the list that appears;
then, follow the instructions on the screen.
Diagnostics
21
Summary of Contents for Netfinity 5100 8658 1RY
Page 1: ...Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY S10K 2615 00...
Page 10: ...x Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 26: ...16 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 50: ...40 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 65: ...13 PCI slot 2 32 bit J32 Installing options 55...
Page 195: ...Parts listing Type 8658 Copyright IBM Corp 2000 185...
Page 196: ...186 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 215: ...Related service information 205...
Page 216: ...206 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 217: ...Related service information 207...
Page 218: ...208 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 219: ...Related service information 209...
Page 220: ...210 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 221: ...Related service information 211...
Page 222: ...212 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 235: ...Related service information 225...
Page 236: ...226 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Page 237: ...Related service information 227...
Page 245: ......
Page 246: ...Part Number 10K2615 Printed in U S A S10K 2615 00 1P P N 10K2615...