Some occurrences of errors in the system might not appear in the sensor status. After you view the sensor
status, look for event codes to determine whether a service action is required.
Removing and replacing covers on an 8335-GTC, 8335-GTG, 8335-
GTH, 8335-GTW, or 8335-GTX system
Learn how to remove and replace the covers for an IBM Power System AC922 (8335-GTC, 8335-GTG, and
8335-GTH) or IBM Power System AC922 (8335-GTW and 8335-GTX) system so that you can access the
hardware parts or service the system.
Removing the service access cover from an 8335-GTC, 8335-GTG, 8335-
GTH, 8335-GTW, or 8335-GTX system
To remove the service access cover, complete the steps in this procedure.
Procedure
1. Ensure that you removed both power supplies from the system.
For instructions, see “Preparing the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX
system to remove and replace internal parts” on page 32.
(L005)
CAUTION: Hazardous energy present. Voltages with hazardous energy might cause heating
when shorted with metal, which might result in splattered metal, burns, or both. (L005)
2. At the rear of the system, loosen the cover screw (A) that fastens the cover to the chassis.
40 Power Systems: Installing and Servicing the OpenCAPI adapter support for the 8335-GTH system