1.
Bring-up
failure
2.
Run-time
non-recoverable
failure
3.
Run-time
recoverable
failure
4.
Group
integrity
failure
5.
Non-repeat-gardable
error.
The
resource
may
be
reconfigured
on
the
next
boot.
A
status
of
00
indicates
that
the
CPU
has
not
had
any
errors
logged
against
it
by
the
service
processor.
To
enable
or
disable
CPU
repeat
gard,
use
menu
option
77.
CPU
repeat
gard
is
enabled
by
default.
If
CPU
repeat
gard
is
disabled,
processors
that
are
in
the
″
deconfigured
by
system
″
state
will
be
reconfigured.
These
reconfigured
processors
are
then
tested
during
the
boot
process,
and
if
they
pass,
they
remain
online.
If
they
fail
the
boot
testing,
they
are
deconfigured
even
though
CPU
repeat
gard
is
disabled.
The
failure
history
of
each
CPU
is
retained.
If
a
processor
with
a
history
of
failures
is
brought
back
online
by
disabling
repeat
gard,
it
remains
online
if
it
passes
testing
during
the
boot
process.
However,
if
repeat
gard
is
enabled,
the
processor
is
taken
offline
again
because
of
its
history
of
failures.
Notes:
1.
The
processor
numbering
scheme
used
by
the
service
processor
is
different
from
the
numbering
scheme
used
by
AIX.
Consult
the
AIX
documentation
before
configuring
or
deconfiguring
a
processor
to
ensure
that
the
correct
processor
is
selected.
2.
The
number
of
processors
available
to
AIX
can
be
determined
by
issuing
the
following
command
on
the
AIX
command
line:
bindprocessor
-q
Note:
The
number
of
processors
available
to
Linux
can
be
determined
by
issuing
the
following
command
on
the
Linux
command
line:
cat
/proc/cpuinfo
|
grep
POWER
v
Memory
Configuration/Deconfiguration
Menu
Enable/Disable
Memory
Repeat
Gard
Memory
repeat
gard
will
automatically
deconfigure
a
quad
of
memory
during
a
system
boot
if
a
memory
DIMM
has
failed
BIST
(built-in
self-test),
caused
a
machine
check
or
check
stop,
or
has
reached
a
threshold
of
recoverable
errors.
The
quad
will
remain
deconfigured
until
repeat
gard
is
disabled
or
the
memory
is
replaced.
The
default
is
enabled.
For
more
information,
see
“Configuring
and
Deconfiguring
Processors
or
Memory”
on
page
256.
Runtime
Recoverable
Error
Repeat
Gard
The
runtime
recoverable
error
repeat
gard
flag
controls
the
deallocation
of
the
memory
if
a
recoverable
error
occurs
during
runtime.
If
a
recoverable
memory
error
occurs,
and
runtime
recoverable
error
repeat
gard
is
disabled,
the
system
will
continue
running
with
no
change
in
the
memory
configuration.
If
a
recoverable
memory
error
occurs,
and
runtime
recoverable
error
repeat
gard
is
enabled,
the
memory
quad
in
which
the
error
occurred
will
be
garded
out
(taken
offline).
The
default
is
disabled.
These
menus
allow
the
user
to
change
the
system
memory
configuration.
If
it
is
necessary
to
take
one
of
the
memory
DIMMs
offline,
this
menu
allows
you
to
deconfigure
a
DIMM,
and
then
reconfigure
the
DIMM
at
a
later
time.
When
this
option
is
selected,
a
menu
displays.
The
following
is
an
example
of
this
menu:
240
Eserver
pSeries
615
Service
Guide
Summary of Contents for P 615 series
Page 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 2: ......
Page 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 12: ...x EserverpSeries 615 Service Guide...
Page 16: ...xiv EserverpSeries 615 Service Guide...
Page 18: ...xvi EserverpSeries 615 Service Guide...
Page 58: ...38 EserverpSeries 615 Service Guide...
Page 72: ...52 EserverpSeries 615 Service Guide...
Page 150: ...130 EserverpSeries 615 Service Guide...
Page 178: ...158 EserverpSeries 615 Service Guide...
Page 284: ...264 EserverpSeries 615 Service Guide...
Page 384: ...364 EserverpSeries 615 Service Guide...
Page 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Page 394: ...374 EserverpSeries 615 Service Guide...
Page 418: ...398 EserverpSeries 615 Service Guide...
Page 422: ...402 EserverpSeries 615 Service Guide...
Page 438: ...418 EserverpSeries 615 Service Guide...
Page 448: ...428 EserverpSeries 615 Service Guide...
Page 452: ...432 EserverpSeries 615 Service Guide...
Page 489: ......
Page 490: ...Printed in U S A October 2003 SA38 0630 02...
Page 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...