66
Table 2-3 Error Symptoms List
Error Symptoms
Action/FRU
NOTE: To diagnose a problem, first find the error symptom in the left column. If
directed to a check procedure, replace the FRU indicated in the check
procedure. If no check procedure is indicated, the first Action/FRU listed in right
column is the most likely cause.
Game port does
not respond or
does not work.
Connect a joystick to the game port, then execute
“Interactive Test/Joystick test” in PC-Doctor diagnostics
program.
System board.
Diagnostic Program
Diagnostics
programs cannot
be executed.
Reboot the system from the diagnostics diskette.
Load default settings.
Diagnostics diskette.
Memory module.
System board.
Missing diagnostics
files(s).
Diagnostics diskette.
Keyboard
Some or all keys on
keyboard do not
work.
“Keyboard“ on page 75.
Power Supply
Pressing power
switch cannot turn
off system.. (Only
unplug power cord
from electrical
outlet can turn off
system.)
See ”Power Management Setup” on page 48.
Power switch cable assembly
"Power Supply" on page 77.
System board
Pressing power
switch cannot turn
on system..
Check the voltage selector on the power supply if it is off.
Power switch cable assembly.
Executing software
shutdown from
Windows98 Start
menu cannot turn
off system. (Only
pressing power
switch can force
system to turn off).
Load default settings.
Reload software from Recovery CD.
No system power,
or power supply fan
is not running.
"Power Supply" on page 77.
System board.
Other Problems
Any other
problems.
“Undetermined Problems” on page 80.
Summary of Contents for PC 300
Page 11: ...11...
Page 12: ...12...
Page 13: ...13...
Page 14: ...14...
Page 15: ...15...
Page 25: ...25...
Page 26: ...26...
Page 27: ...27...
Page 34: ...34...
Page 86: ...86...
Page 110: ...110...
Page 129: ...129 Hard Drive or CD ROM Power Cable Connector 3 5 In Diskette Drive Power Cable Connector...
Page 139: ...139 Safety Inspection Guide General Guidelines 140...