POST Message
Description
1962
A startup sequence error occurred.
Action:
1. Make sure the settings for startup options are correct in the
Configuration/Setup Utility program. If the settings are not
correct, change and save them. For instructions, see “Using
the Configuration/Setup Utility Program” on page 33.
2. Make sure the primary IDE (or, if applicable, SCSI) cable is
properly installed and securely connected.
3. Make sure all adapters are installed correctly. For instructions
on adding adapters, see Installing Options in Your Personal
Computer.
If the problem cannot be isolated and corrected, have the computer
serviced.
2462
A video configuration error occurred.
Action:
1. Make sure the monitor signal cable is securely attached to the
monitor connector. (For the location of the monitor connector,
refer to “Connectivity” on page 10.)
2. If you just added or removed video memory, you must save
the new configuration in the Configuration/Setup Utility
program. Refer to the Important text box on page 34 for
further information and instructions on saving the
configuration.
If the problem cannot be isolated and corrected, have the computer
serviced.
I9990301
A hard disk failure occurred.
Action:
Have the computer serviced.
Other Numbers
The computer POST found an error.
Action:
Follow the instructions on the screen.
84
Using Your Personal Computer
Summary of Contents for PC 300PL Types 6862
Page 1: ...Personal Computer Using Your Personal Computer PC 300PL...
Page 2: ......
Page 3: ...Personal Computer Using Your Personal Computer PC 300PL IBM...
Page 12: ...x Using Your Personal Computer...
Page 46: ...32 Using Your Personal Computer...
Page 70: ...56 Using Your Personal Computer...
Page 145: ......
Page 146: ...IBM Part Number 06J0871 Printed in U S A July 1997 6J 871...