About the Test Programs
F10
Displays the Local Menu when the Module
Tests Menu is displayed or from individual
Test Group test screens. The Local Menu
includes the following selections:
Test Options
serves as a shortcut to
accessing and changing the test options
without having to back up through
menus.
Single Test
moves from the (Module Test
Menu) to the relevant Test Group window
for test selection.
Next and Previous LUN
changes from
one Logical Unit Number (LUN) or device
to another (for example, HD1 to HD2, or
Base Memory to Extended Memory).
+
Displays next logical unit number (only used
in the Test Module menu and Test Group
screens).
−
Displays previous logical unit number (only
used in the Test Module menu and Test
Group screens).
Using the Command Line Options
The following Command Line Options allow you to define specific
conditions for running the diagnostic programs at startup time.
At the operating system prompt, type
QAPRO /XXX
(where
/XXX
represents one of the following); then press Enter.
/B&W
The /B&W option forces the program to load
in black and white (monochrome) mode.
/LOG=
file
The /LOG=file option directs the test programs
to start using a specified Error Log file. Note
that file is the name of the Error Log file that
you specify.
Chapter 5. Solving Problems
237
Summary of Contents for PC Server 330
Page 1: ...PC Server 330 User s Handbook IBM...
Page 6: ...vi PC Server 330 User s Handbook...
Page 10: ...x PC Server 330 User s Handbook...
Page 32: ...18 PC Server 330 User s Handbook...
Page 100: ...86 PC Server 330 User s Handbook...
Page 134: ...120 PC Server 330 User s Handbook...
Page 240: ...Updating the Server Configuration 226 PC Server 330 User s Handbook...
Page 326: ...Resolving Configuration Conflicts 312 PC Server 330 User s Handbook...
Page 382: ...IBM Part Number 76H8834 Printed in U S A September 1996 76H8834...