ServeRAID Adapter Messages
Configured Drives Are Not in the Configured Location
When the ServeRAID adapter detects that a previously configured
drive is present, but the drive is in a new location, the following
message appears:
(old ch: old bay:
>
new ch: new bay)
where old ch is the channel that matches the existing drive
configuration information, old bay is the bay that matches the
existing drive configuration information, new ch is the channel
where the drive is now located, and new bay is the bay where the
drive is now located.
For example:
(2 :5
>
2: 6)
In this example, the message indicates that the drive from Channel
2, Bay 5 is now located at Channel 2, Bay 6. The drive might have
been physically moved to the new bay.
Three choices will follow this message:
F4
Retry. Select this key after correcting a problem. For
example, select retry after you move the hard disk drive
to its previously assigned location.
F5
Select this key to accept the new state that the
ServeRAID adapter will assign to the drive. For
example, the adapter will assign the drive a state of
defunct.
F6
Select this key to modify the configuration to match the
current drive location.
You might remove the hot-swap drives from the server
for security reasons. If you replace the drives but install
them in different bays, you can press F6 to accept the
new locations, and the ServeRAID adapter will update
the configuration.
284
PC Server 330 User's Handbook
Summary of Contents for PC Server 330
Page 1: ...PC Server 330 User s Handbook IBM...
Page 6: ...vi PC Server 330 User s Handbook...
Page 10: ...x PC Server 330 User s Handbook...
Page 32: ...18 PC Server 330 User s Handbook...
Page 100: ...86 PC Server 330 User s Handbook...
Page 134: ...120 PC Server 330 User s Handbook...
Page 240: ...Updating the Server Configuration 226 PC Server 330 User s Handbook...
Page 326: ...Resolving Configuration Conflicts 312 PC Server 330 User s Handbook...
Page 382: ...IBM Part Number 76H8834 Printed in U S A September 1996 76H8834...