Unattended Mode of Operation
You can enable the adapter to accept changes in the configuration
without user input. When this mode is enabled (refer to
“Display/Change the ServeRAID Adapter Parameters” on page 79
for information), the adapter pauses briefly to permit a user to
override the default action; then the adapter makes the necessary
changes. Unattended mode, also clears any blocked drives. This
mode is useful when the server operates remotely.
The adapter “chooses” an action that is equivalent to pressing one
of the function keys in the following order.
F5
: The server continues the startup operation after identifying the
drive that is defunct. For example, a HSP drive failed to respond
during POST. Startup continues without the HSP drive; its drive
state will display as DHS.
F6
: When a drive has been removed from the server, for example,
for maintenance or security, and was returned, but in a different
bay, the adapter adjusts the configuration to the drive's new
location.
F7
: An adapter with stored configuration information that does not
match that of the configured drives present, import the
configuration information from the drives. Refer to “ServeRAID
Adapter Messages” on page 282 for more information.
72
PC Server 330 User's Handbook
Summary of Contents for PC Server 330
Page 1: ...PC Server 330 User s Handbook IBM...
Page 6: ...vi PC Server 330 User s Handbook...
Page 10: ...x PC Server 330 User s Handbook...
Page 32: ...18 PC Server 330 User s Handbook...
Page 100: ...86 PC Server 330 User s Handbook...
Page 134: ...120 PC Server 330 User s Handbook...
Page 240: ...Updating the Server Configuration 226 PC Server 330 User s Handbook...
Page 326: ...Resolving Configuration Conflicts 312 PC Server 330 User s Handbook...
Page 382: ...IBM Part Number 76H8834 Printed in U S A September 1996 76H8834...