Running RAID Subsystem Diagnostics
Identified HDD as Source
updates the configuration
information with stored configuration information on a hard
disk drive that matches the identifiers stored in the NVRAM.
The updated configuration information is then copied to
NVRAM, the adapter EEPROM, and the hard disk drives
configured in an array.
Specific HDD as Source
retrieves the configuration information
with stored configuration information on the hard disk drive
that you select. The updated configuration information is then
copied to NVRAM, EEPROM, and configured hard disk drives.
Running RAID Subsystem Diagnostic Tests
The ServeRAID Subsystem Diagnostic program provides several
utility programs that allow you to test the ServeRAID adapter and
the devices connected to it.
To run the RAID diagnostic utility programs, do the following steps:
1. Start the ServeRAID configuration program (see “Starting the
ServeRAID Configuration Program” on page 80).
2. Select Advanced Functions from the Main Menu.
3. Select IBM RAID Subsystem Diagnostic.
4. Select the diagnostic test that you want to run and press Enter:
Run Adapter Self-test
runs diagnostic tests on the
ServeRAID adapter.
SCSI Device Self-test
runs diagnostic tests on the SCSI
devices attached to the ServeRAID adapter.
Drive Media Test
verifies that all sectors on a hard disk
drive can be accessed. The drive must be in the RDY or
HSP state.
Format Drive
performs a low-level format on a hard disk
drive. For more information, see “Formatting Drives” on
page 120.
5. Follow the instructions on the screen.
Chapter 3. Configuring the Disk Array
115
Summary of Contents for PC Server 520
Page 1: ...PC Server 520 User s Handbook for PCI Micro Channel IBM...
Page 86: ...Installation Checklist 70 PC Server 520 User s Handbook for PCI Micro Channel...
Page 146: ...Using the Mini Configuration Program 130 PC Server 520 User s Handbook for PCI Micro Channel...
Page 190: ...Using the SCSISelect Utility Program 174 PC Server 520 User s Handbook for PCI Micro Channel...
Page 385: ...Installing Additional Test Programs 207 CMD 3 Chapter 7 Solving Problems 369...
Page 438: ...IBM Part Number 78H6336 Printed in U S A May 1996 78H6336...