No
Go to step 3.
Yes
Continue with the next step.
2.
Run stand-alone diagnostics either from a CD or from a Network Installation Management (NIM)
server.
Did you encounter any problems?
No
Reinstall the operating system and continue with step 5.
Yes
If the original problem still exists, replace the field-replaceable unit (FRU) or perform the
isolation procedure that is next in the FRU list. If you have reached the end of the FRU list,
contact your next level of support.
If a new problem has occurred, go to Beginning problem analysis.
3.
Did you replace a FRU with the power turned on and concurrently with system operations?
No
Go to step 5.
Yes
Continue with the next step.
4.
Did you use an AIX diagnostics service aid hot-swap operation to change the FRU?
No
Go to step 7.
Yes
Go to step 6.
Note:
The AIX diagnostic service aid was used if a resource was removed by using the Hot Plug
task.
5.
If any FRUs have been removed that should be reinstalled, reinstall them now:
a.
If the system is not powered on, power it on now.
b.
Wait until the AIX operating system login prompt is displayed or until system activity on the
operator panel or display has stopped.
c.
Did you encounter any problems?
No
Continue at step 6.
Yes
If the original problem still exists, replace the FRU or perform the isolation procedure that is
next in the FRU list. If you have reached the end of the FRU list, contact your next level of
support.
If a new problem occurs, go to Beginning problem analysis.
6.
If the Resource Repair Action menu is already displayed, go to step 9 on page 77; otherwise, perform
the following steps:
a.
Log into the operating system either with root authority (if needed, ask the customer to enter the
password) or use the CE login.
b.
Enter
diag -a
command and check for missing resources. Follow any instructions that are
displayed. If an SRN displays, suspect a loose card or connection. If no instructions are
displayed, no resources were detected as missing. Continue with the next step.
7.
Perform the following steps:
a.
Enter
diag
at the command prompt.
b.
Press Enter.
c.
Select the Diagnostics Routines option.
d.
When the Diagnostic Mode Selection menu is displayed, select System verification.
e.
When the Diagnostic Selection menu is displayed, select the All Resources option or test the
FRUs you exchanged and any devices that are attached to the FRUs you exchanged by selecting
the diagnostics for the individual FRU.
Did the Resource Repair Action menu (801015) display?
76
PCIe3 x8 SAS RAID internal adapter 6 Gb
Summary of Contents for PCIe3 x8 SAS RAID internal adapter 6 Gb
Page 2: ......
Page 8: ...vi PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 18: ...xvi PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 36: ...18 PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 118: ...100 PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Page 129: ...Notices 111 ...
Page 130: ...IBM Printed in USA ...