18
IBM Power 595 Technical Overview and Introduction
Existing HMC models 7310 can be upgraded to Licensed Machine Code Version 7 to support
environments that can include POWER5, , and POWER6 processor-based
servers. Version 7 is not available for the 7315 HMCs. Licensed Machine Code Version 6
(#0961) is not available for 7042 HMCs, and Licensed Machine Code Version 7 (#0962) is not
available on new 7310 HMC orders.
1.3.7 Model conversion
Clients with installed p5-590, p5-595, i5-595, and i5-570 servers can increase their computing
power by ordering a model conversion to the 595 server. Table 1-15 lists the available model
conversions.
Table 1-15 Available model conversions
Due to the size and complex nature of the
miscellaneous equipment specification (
MES)
model upgrades into the Power 595 server, a two-step MES process is required. The two
MESs are configured in a single eConfig session (the ordering tool used by sales and
technical professionals) and contained within the same eConfig Proposed Report. These
MESs are processed in sequence.
The initial MES is a Record Purpose Only (RPO) activity that positions the inventory record
and conceptually redefines the installed product with Power Systems feature nomenclature.
This MES contains a series of RPO feature additions and removals within the installed
machine type and model, and adds specify code #0396. This RPO MES serves several
purposes. It keeps your maintenance billing whole throughout the upgrade process, reduces
the number of feature conversions on the normal MES, and reduces the overall size of the
normal MES. This RPO MES should be stored in a separate eConfig file for reference prior to
order forward.
The second MES is a normal machine/model upgrade MES from 9406/9119 to 9119-FHA
with all the appropriate model/feature conversions and subject to the usual scheduling,
manufacturing, and installation rules and processes. Care must be taken that both MESs are
processed completely through installation prior to configuration/placement of any subsequent
MES orders.
From type-model
To type-model
9119 590
9119 FHA
9119 595
9119 FHA
9406 570
9119 FHA
9406 595
9119 FHA
Note:
In the event that the RPO MES is reported as installed and the normal MES is
cancelled, a sales representative must submit an additional RPO MES reversing the
transactions of the initial RPO MES to return your inventory record to its original state.
Failure to do so prevents future MES activity for your machine and could corrupt your
maintenance billing. The saved eConfig Proposed Report can be used as the basis for
configuring this reversal RPO MES.
Summary of Contents for Power 595
Page 2: ......
Page 120: ...108 IBM Power 595 Technical Overview and Introduction...
Page 182: ...170 IBM Power 595 Technical Overview and Introduction...
Page 186: ...174 IBM Power 595 Technical Overview and Introduction...
Page 187: ......