56
IBM Power 595 Technical Overview and Introduction
A maximum of four adapters can be installed in each 8-core processor book: two wide and
two narrow. Beginning with the adapter slot closest to Node Controller 0, the slots alternate
narrow-wide-narrow-wide. GX slots T and U are narrow; S and V are wide.
Figure 2-16 details the GX adapter layout for a two-processor book.
Figure 2-16 GX adapter placement
For I/O hub plugging rules, see section 2.8, “Internal I/O subsystem” on page 82.
Figure 2-17 on page 57 shows the cabling order when connecting I/O drawers to the I/O
hubs. The numbers on the left show the sequence in which the I/O hubs are selected for
cabling to the drawers. The designation on the left indicates the drawer location that the
cables will run to. “A’ indicates system rack. P-A indicates a powered expansion rack (not
shown), and P-Z indicates a nonpowered expansion rack attached to a powered expansion
rack. The numbers at the right indicate the rack location for the bottom edge of the drawer.
For example, A-01 is the drawer in the system rack, located at U1 (first I/O drawer) and A-09
is the drawer in the system rack, located at U9 (third I/O drawer).
Lower Node
GX
I/O Hub
Adapters
Node
Controllers
GX
I/O Hub
Adapters
Upper Node
Lower Node
Wide GX Slots
GX-V
GX-S
Narrow GX Slots
GX-U
GX-T
Upper Node
(Node Controller 1)
I/O Hub Slot GX - T
I/O Hub Slot GX - S
I/O Hub Slot GX - U
I/O Hub Slot GX - V
I/O Hub Slot GX - S
I/O Hub Slot GX - T
I/O Hub Slot GX - U
I/O Hub Slot GX - V
Mid-plane
(Node Controller 0)
(Node Controller 0)
(Node Controller 1)
Upper Node
(Node Controller 1)
I/O Hub Slot GX - T
I/O Hub Slot GX - S
I/O Hub Slot GX - U
I/O Hub Slot GX - V
I/O Hub Slot GX - S
I/O Hub Slot GX - T
I/O Hub Slot GX - U
I/O Hub Slot GX - V
Mid-plane
(Node Controller 0)
(Node Controller 0)
(Node Controller 1)
Node
Controllers