Power775 Disk Enclosure Fan Service Procedure
25 of 61
3.6 Move UEPO Panel <= SSR TASK
STEP 14
Is the Disk Enclosure being serviced located in U21 or U25 (see Figure 14)?
•
If “YES”, then go to STEP 15.
•
If “NO”, then go to STEP 19.
Figure 14: Disk Enclosure and UEPO Location Info
STEP 15
DO NOT
disconnect the UEPO cables and
DO NOT
put the UEPO switch in the “OFF” position. Loosen the
blue-colored thumb screw located at the bottom of the UEPO using the Hex Driver torque tool PN 41V1059 (4mm
Hex Driver 1.5-1.75 Nm) provided in the tool kit.
STEP 16
Unhook the UEPO switch assembly from the Rack by sliding it upward and then away from the Rack.