Solid-state drives (SSDs), also known as flash drives, follow similar rules as regular hard disk drives
(HDDs). For example, SSDs physically resemble, install in the same manner, and in most of the same
slots as HDDs. However, some restrictions and configuration rules are specific to the SSD.
After you review the configuration rules, you can install the drive as you would any other disk drive.
Attention:
Before you install an SSD in your system, ensure that both the SSD and the adapters have all
the prerequisite updates. To check for the prerequisites, go to the IBM Prerequisite website(www-
912.ibm.com/e_dir/eServerPrereq.nsf).
The following tables help you to determine the operating system, adapter, machine type model, and disk
drive configuration rules that apply to your system or disk drive enclosure.
Restriction:
Solid-state drives must be part of a RAID array or system mirroring in the system or logical
partition that is controlled by IBM i.
Choose the system or enclosure you want to view the configuration rules for:
v
Solid-state drive rules for the 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A
v
Solid-state drive rules for the 8247-42L, 8286-41A, or 8286-42A
v
Solid-state drive rules for the 8408-44E or 8408-E8E
v
Solid-state drive rules for the 5887 disk drive enclosure
v
Note:
The ESLL storage enclosure does not use solid-state drives.
Solid-state drive rules for the 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A
Table 1. Solid-state drive rules for the 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A system.
System
Adapter
Mixing rules
8247-21L or 8247-22L
PCIe3 x8 SAS RAID
internal adapter 6 Gb (FC
EL3V; CCIN 57D7)
v
FC EL3V can be used to split the disk backplane into two
sets of 6 disks.
v
HDDs can be configured as just a bunch of disks (JBOD) or
in RAID 0, 5, 6, and 10.
v
SSDs must be configured in RAID 0, 5, 6, or 10.
v
SSDs and HDDs can be mixed within each side of a split
disk backplane, but cannot be mixed in the same RAID
array.
8284-21A or 8284-22A
PCIe3 x8 SAS RAID
internal adapter 6 Gb (FC
EJ0V; CCIN 57D7)
v
FC EJ0V can be used to split the disk backplane into two
sets of 6 disks.
v
HDDs can be configured as JBOD or in RAID 0, 5, 6, and
10.
v
SSDs must be configured in RAID 0, 5, 6, or 10.
v
SSDs and HDDs can be mixed within each side of a split
disk backplane, but cannot be mixed in the same RAID
array.
Solid-state drive rules for the 8247-42L, 8286-41A, or 8286-42A
Disk drives or solid-state drives
105
Summary of Contents for Power System 5148-21L
Page 2: ......
Page 18: ...xvi Disk drives or solid state drives ...
Page 202: ...184 Disk drives or solid state drives ...
Page 203: ......
Page 204: ...IBM ...