d.
Verify that the disk drive or solid-state drive that you installed is shown on this display.
7.
To configure the newly installed disk drive or solid-state drive, see “Configuring a disk drive or
solid-state drive for use in an Linux system or Linux logical partition” on page 118.
Removing and replacing a disk drive or solid-state drive in the
5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A
Find information about removing and replacing a serial-attached SCSI (SAS) disk drive or a solid-state
drive (SSD) in a system.
If you are removing and replacing a disk drive or solid-state drive in a 5887 disk drive enclosure or
5147-024, ESLL, or ESLS storage enclosure, see Removing and replacing a disk drive or solid-state drive
in the 5887 disk drive enclosure(http://www.ibm.com/support/knowledgecenter/POWER8/p8hal/
p8hal_5887_rnr_kickoff.htm) or Removing and replacing a disk drive or solid-state drive in the 5147-024,
ESLL, or ESLS storage enclosure storage enclosure(http://www.ibm.com/support/knowledgecenter/
POWER8/p8hal/p8hal_eslx_rnr_kickoff.htm).
Removing and replacing a disk drive or solid-state drive in the
5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A with
the system power turned off
Learn how to remove and replace a disk drive or solid-state drive (SSD) in a system with the system
power turned off.
To remove and replace a disk drive or solid-state drive in a system, complete the following steps:
1.
2.
3.
4.
Display Hardware Status
Type option, press Enter.
1=Display hardware resource information details
OPT Name
PCI/SCSI Location
Description
Status
--- ------ -------------------------- ------------------------- ----------------
0000:01:00.0/0:
PCI-E SAS RAID Adapter
Operational
0000:01:00.0/0:0:0:0
Advanced Function SSD
Active
0000:01:00.0/0:0:1:0
Advanced Function SSD
Active
0000:01:00.0/0:0:2:0
Advanced Function SSD
Active
0000:01:00.0/0:0:3:0
Advanced Function SSD
Active
0000:01:00.0/0:0:4:0
Advanced Function SSD
Active
0000:01:00.0/0:0:5:0
Advanced Function SSD
Active
0000:01:00.0/0:0:6:0
Advanced Function SSD
Active
0000:01:00.0/0:0:8:0
Enclosure
Active
0000:01:00.0/0:0:9:0
Enclosure
Active
0001:01:00.0/1:
PCI-E SAS RAID Adapter
Operational
0001:01:00.0/1:0:3:0
Advanced Function SSD
Remote
0001:01:00.0/1:0:4:0
Advanced Function SSD
Remote
0001:01:00.0/1:0:5:0
Advanced Function SSD
Remote
More...
e=Exit
q=Cancel
r=Refresh
t=Toggle
f=PageDn
b=PageUp
Figure 37. Example Display Hardware Status
38
Disk drives or solid-state drives
Summary of Contents for Power System 5148-21L
Page 2: ......
Page 18: ...xvi Disk drives or solid state drives ...
Page 202: ...184 Disk drives or solid state drives ...
Page 203: ......
Page 204: ...IBM ...