9.
Locate the disk drive or solid-state drive to be replaced and record the location information. Then,
use the location information to activate the identify light for that drive. For instructions, see “Finding
the location code and activating the indicator light for a part by using the IBM i operating system”
on page 130.
10.
Determine whether the disk drive or solid-state drive to be removed is a non-configured drive by
completing the following steps:
a.
Type
strsst
on the command line of the IBM i session, and then press
Enter
.
b.
Type your service tools user ID and service tools password, and then press
Enter
.
c.
Select Work with disk units, and then press
Enter
.
d.
Select Display Disk Configuration, and then press
Enter
.
e.
Select Display non-configured units, and then press
Enter
.
11.
Is the failed drive listed as a non-configured drive in the display?
v
No
: Continue to step 14.
v
Yes
: Continue to step 12.
12.
Determine whether the disk drive or solid-state drive to be removed was replaced by a hot-spare
drive when it failed by completing the following steps:
a.
Go to the service action log. For instructions to access the service action log, see “Finding the
location code and activating the indicator light for a part by using the IBM i operating system”
on page 130.
b.
Determine whether an
xxxx9031
error was logged close to the same time as the original disk
failure. This error indicates that the data to the hot-spare drive was automatically rebuilt.
c.
Determine whether an error was logged for the field-replaceable unit (FRU) by using concurrent
maintenance. If yes, continue with the next step.
13.
Did you find the service action log entry that is related to this problem?
v
No
: Exit the service action log and go to step 15.
v
Yes
: Continue with the next step.
14.
Within the service action log, select the concurrent maintenance option. This option displays the
drive location on the concurrent maintenance display. Go to step 17 on page 62.
15.
From the Hardware Service Manager, navigate to Select Device Concurrent Maintenance option.
Press
Enter
. The Device Concurrent Maintenance display is shown, as shown in the Figure 60 on
P2-D14
P2-D12
P2-D10
P2-D13
P2-D1
1
P2-D9
P2-D8
P2-D7
P2-D6
P2-D5
P2-D4
P2-D3
P2-D2
P2-D1
P8HAL509-1
Figure 59. Disk drive, solid-state drive, and service indicator locations for an expanded function system
Disk drives or solid-state drives
61