Response:
Check for events FQPSPPW0047M,
FQPSPPW0048M, FQPSPPW0049M, FQPSPPW0050M,
FQPSPPW0051M, FQPSPPW0052M and
FQPSPPW0053M and resolve those first, in that order.
If the problem persists, replace CPU 1. If the problem
persists replace the system backplane.
FQPSPPW0059M
Explanation:
Message: The power sequencer chip
detected a fault on VDD-A rail.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response:
Check for events FQPSPPW0047M,
FQPSPPW0048M, FQPSPPW0049M, FQPSPPW0050M,
FQPSPPW0051M, FQPSPPW0052M and
FQPSPPW0053M and resolve those first, in that order.
If the problem persists, replace CPU 0. If the problem
persists replace the system backplane.
FQPSPPW0060M
Explanation:
Message: The power sequencer chip
detected a fault on VDD-B rail.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response:
Check for events FQPSPPW0047M,
FQPSPPW0048M, FQPSPPW0049M, FQPSPPW0050M,
FQPSPPW0051M, FQPSPPW0052M and
FQPSPPW0053M and resolve those first, in that order.
If the problem persists, replace CPU 1. If the problem
persists replace the system backplane.
FQPSPPW0061M
Explanation:
Message: The power sequencer chip
detected a fault on VCS-A rail.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response:
Check for events FQPSPPW0047M,
FQPSPPW0048M, FQPSPPW0049M, FQPSPPW0050M,
FQPSPPW0051M, FQPSPPW0052M and
FQPSPPW0053M and resolve those first, in that order.
If the problem persists, replace CPU 0. If the problem
persists replace the system backplane.
FQPSPPW0062M
Explanation:
Message: The power sequencer chip
detected a fault on VCS-B rail.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response:
Check for events FQPSPPW0047M,
FQPSPPW0048M, FQPSPPW0049M, FQPSPPW0050M,
FQPSPPW0051M, FQPSPPW0052M and
FQPSPPW0053M and resolve those first, in that order.
If the problem persists, replace CPU 1. If the problem
persists replace the system backplane.
FQPSPPW0063G
Explanation:
Message: The system unexpectedly
shutdown.
Severity: Warning
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Unrecoverable Hardware Failure
Response:
Look for serviceable system events that are
related to system power and occurred around the same
time as the problem that you are working on and
resolve those first.
FQPSPPW0064M
Explanation:
Message: Power supply input fault
detected, but unable to isolate to a specific power
supply
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Unrecoverable Hardware Failure
Response:
Verify the line cords are securely seated to
both power supplies.
FQPSPSB0001M
Explanation:
Message: The system backplane has
encountered a critical failure.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: System Board
Event type: Uncorrectable Hardware Failure
Response:
Replace the system backplane.
FQPSPPW0059M • FQPSPSB0001M
14
Event Codes for the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, and 8335-GTX
Summary of Contents for Power System 8335-GTC
Page 1: ...Power Systems Event Codes for the 8335 GTC 8335 GTG 8335 GTH 8335 GTW and 8335 GTX IBM...
Page 2: ......
Page 3: ...Power Systems Event Codes for the 8335 GTC 8335 GTG 8335 GTH 8335 GTW and 8335 GTX IBM...
Page 6: ...iv Event Codes for the 8335 GTC 8335 GTG 8335 GTH 8335 GTW and 8335 GTX...
Page 16: ...xiv Event Codes for the 8335 GTC 8335 GTG 8335 GTH 8335 GTW and 8335 GTX...
Page 32: ...16 Event Codes for the 8335 GTC 8335 GTG 8335 GTH 8335 GTW and 8335 GTX...
Page 44: ...28 Event Codes for the 8335 GTC 8335 GTG 8335 GTH 8335 GTW and 8335 GTX...
Page 45: ......
Page 46: ...IBM...