background image

Power Systems

Installing the System and Ordered Parts

for the IBM Power System AC922 (8335-

GTX)

IBM

Summary of Contents for Power System 8335-GTX

Page 1: ...Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX IBM ...

Page 2: ...l G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER9 processor and to all associated models Copyright International Business Machines Corporation 2018 2020 US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Page 3: ...5 GTG 8335 GTH or 8335 GTX system 20 PCIe adapters by feature code 22 Installing a PCIe adapter in the 8335 GTG 8335 GTH or 8335 GTX system 79 Common procedures for servicing or installing features 82 Before you begin 82 Identifying the system that contains the part to replace 87 Preparing the system to remove and replace internal parts 90 Preparing the system for operation 94 Starting and stoppin...

Page 4: ...iv ...

Page 5: ...800 300 8751 German safety information Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne 2 der Bildschirmarbeitsverordnung geeignet Laser safety information IBM servers can use I O cards or features that are fiber optic based and that utilize lasers or LEDs Laser compliance IBM servers may be installed inside or outside of an IT equipment rack DANGER When working on or aro...

Page 6: ...everything unless instructed otherwise 2 For AC power remove the power cords from the outlets 3 For racks with a DC power distribution panel PDP turn off the circuit breakers located in the PDP and remove the power from the Customer s DC power source 4 Remove the signal cables from the connectors 5 Remove all cables from the devices To Connect 1 Turn off everything unless instructed otherwise 2 At...

Page 7: ... devices that attach to the system It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock R001 part 1 of 2 R001 part 2 of 2 CAUTION Do not install a unit in a rack where the internal rack ambient temperatures will exceed the manufacturer s recommended ambient temperature for all your rack mounted devices Do not install a un...

Page 8: ...that you choose can support the weight of the loaded rack cabinet Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet Verify that all door openings are at least 760 x 230 mm 30 x 80 in Ensure that all devices shelves drawers doors and cables are secure Ensure that the four leveling pads are raised to their highest position Ensure that there is no st...

Page 9: ...y position for example when working from a ladder Stability hazard The rack may tip over causing serious personal injury Before extending the rack to the installation position read the installation instructions Do not put any load on the slide rail mounted equipment mounted in the installation position Do not leave the slide rail mounted equipment in the installation position L002 L003 or or or Sa...

Page 10: ...multiple AC power cords or multiple DC power cables To remove all hazardous voltages disconnect all power cords and power cables L003 L007 CAUTION A hot surface nearby L007 x Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 11: ...king into the other end of a disconnected optical fiber to verify the continuity of optic fibers may not injure the eye this procedure is potentially dangerous Therefore verifying the continuity of optical fibers by shining light into one end and looking at the other end is not recommended To verify continuity of a fiber optic cable use an optical light source and power meter C027 CAUTION This pro...

Page 12: ...hout appreciable force so take care not to push or lean Keep riser tilt adjustable angling platform option flat at all times except for final minor angle adjustment when needed Do not stand under overhanging load Do not use on uneven surface incline or decline major ramps Do not stack loads Do not operate while under the influence of drugs or alcohol Do not support ladder against LIFT TOOL unless ...

Page 13: ...uitable for connection to intrabuilding or unexposed wiring or cabling only The intrabuilding ports of this equipment must not be metallically connected to the interfaces that connect to the OSP outside plant or its wiring These interfaces are designed for use as intrabuilding interfaces only Type 2 or Type 4 ports as described in GR 1089 CORE and require isolation from the exposed OSP cabling The...

Page 14: ...xiv Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 15: ...tions servlet pbi wss This bulletin provides a list of the key IBM system installation activities and a list of activities that might be billable Installing the 8335 GTX system Learn how to install cable and set up your server Prerequisite for installing the rack mounted server Learn about the prerequisites for installing the server Before you begin Read the following documents before you install ...

Page 16: ...Read the Rack safety notices http www ibm com support knowledgecenter POWER9 p9hbf p9hbf_racksafety htm 2 Determine where to place the system unit in the rack As you plan for installing the system unit in a rack consider the following information Organize larger and heavier units into the lower part of the rack Plan to install system units into the lower part of the rack first Record the Electroni...

Page 17: ...eft side of the rack 6 Go to the rear of the rack 7 On the right side find the EIA unit that corresponds to the bottom EIA unit marked on the front of the rack 8 Mark the bottom EIA unit 9 Mark the corresponding hole on the left side of the rack Installing the 8335 GTW or 8335 GTX system by using fixed rails If you ordered the system with the fixed rail option use these procedures to install the s...

Page 18: ...e 4 through 6 on page 4 for the left rail 8 Secure both rails to the front EIA support flange by using two M5 x 16 mm screws Install the screws through the pins that you attached 9 Secure both rails to the rear EIA support flanges by using four M5 x 16 mm screws Install the screws through the pins that you attached Installing the 8335 GTW or 8335 GTX system into the rack by using fixed rails and c...

Page 19: ...manifold as shown in the following figure Ensure that you plug the male hose into the female manifold plug and plug the female hose into the male manifold plug Attention Before powering on the system ensure that cooling water is circulating through the system Installing and configuring the 8335 GTX 5 ...

Page 20: ... server 10 Plug the system power cords and the power cords for any other attached devices into the AC power source 11 Continue with Completing server setup on page 8 Setting up a preinstalled server Use this information to learn how to set up a server that is preinstalled in the rack Prerequisite for installing the rack mounted server Learn about the prerequisites for installing the server Before ...

Page 21: ...ed Note Your order information is included with your product You can also obtain the order information from your marketing representative or the IBM Business Partner If you have incorrect missing or damaged parts consult any of the following resources Your IBM reseller IBM Rochester manufacturing automated information line at 1 800 300 8751 United States only The Directory of worldwide contacts we...

Page 22: ...ords for any other attached devices into the AC power source 6 Continue with Completing server setup on page 8 Completing server setup Learn how to complete server setup Before you begin Note You might be required to set the thermal mode of the system to a setting other than the default setting depending on your system adapter and cable type For details see p9ei3 p9ei3_thermal_mode dita IBM Power ...

Page 23: ...elect Power Firmware find your machine type and model and click Subscribe f Exit the Browse for a product screen g Click Delivery preferences to set email preferences and click Submit h Click Edit to select the types of documentation updates that you want to receive and click Submit 4 You can install the Linux operating system on bare metal systems or on non virtualized systems For these systems t...

Page 24: ...re find your machine type and model and click Subscribe f Exit the Browse for a product screen g Click Delivery preferences to set email preferences and click Submit h Click Edit to select the types of documentation updates that you want to receive and click Submit 4 You can install the Linux operating system on bare metal systems or on non virtualized systems For these systems the operating syste...

Page 25: ... strap follow all electrical safety procedures An ESD wrist strap is used for static control It does not increase or decrease your risk of receiving electric shock when using or working on electrical equipment If you do not have an ESD wrist strap just prior to removing the product from ESD packaging and installing or replacing hardware touch an unpainted metal surface of the system for a minimum ...

Page 26: ...ottom edges as you position the disk drive and insert it into the disk drive slot Important Ensure that the disk drive is fully seated and is all the way into the system 6 Lock the disk drive bay handle A by pushing in the handle release See Figure 7 on page 13 12 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 27: ...s proceed to verifying that the new disk drive is active To run the rescan scsi bus command in the Ubuntu Linux operating system log in to the system as the root user and run the following command rescan scsi bus The rescan scsi bus tool is available in the scsitools package install the package by using the following command sudo apt get install scsitools Red Hat Enterprise Linux RHEL To run the r...

Page 28: ...ry modules The supported memory module sizes are either 8 GB 16 GB 32 GB or 128 GB Mixing of memory module feature codes is not allowed Table 1 on page 14 lists the supported memory feature codes Table 1 Memory feature codes Supported feature codes FC Size EM60 8 GB EM61 16 GB EM63 32 GB EM64 64 GB EM65 128 GB Upgrading memory modules in the 8335 GTX system To upgrade memory modules complete the s...

Page 29: ...cing hardware touch an unpainted metal surface of the system for a minimum of 5 seconds If at any point in this service process you move away from the system it is important to again discharge yourself by touching an unpainted metal surface for at least 5 seconds before you continue with the service process Remove the existing memory modules 2 Remove the air baffles A and B as shown in Figure 8 on...

Page 30: ...ck each memory module by pushing the locking tabs away from the memory module in the direction shown in Figure 10 on page 17 The lever action of opening the tabs pushes the memory module out of the slot 16 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 31: ...an ESD mat 6 Repeat steps 4 on page 16 5 on page 17 until all the memory modules are removed Install the memory modules 7 To install memory modules complete the following steps a Push the locking tabs to the open position away from the slot in the direction shown in Figure 11 on page 18 Installing and configuring the 8335 GTX 17 ...

Page 32: ...mory connector before you attempt to install it c Press firmly on each side of the memory module until the locking tab locks in place with an audible click 8 Repeat step 7 on page 17 until all of the memory modules are installed 9 Replace the air baffles A and B as shown in Figure 12 on page 19 Carefully move the baffles around the hoses 18 Power Systems Installing the System and Ordered Parts for...

Page 33: ...ation about removing installing using and managing Peripheral Component Interconnect Express PCIe adapters for the system Installing this feature is a customer task You can complete this task yourself or contact a service provider to complete the task for you You might be charged a fee by the service provider for this service The features that are listed in Table 2 on page 20 are electromagnetic c...

Page 34: ...ponent Interconnect Express PCIe adapters that are supported for the system PCIe slot descriptions The system provides PCIe generation 4 slots Table 3 on page 20 lists the PCIe adapter slots and details for the system as viewed from the rear and going from left to right Figure 13 on page 20 shows the rear view of the system with the PCIe adapter slots The system supports half height half length an...

Page 35: ...onnectX 5 CAPI capable adapter FC EC64 CCIN 2CF2 Adapter FRU number 00W176 2 3 4 3 EC67 PCIe4 x16 2 port 100 Gb RoCE En ConnectX 5 adapter FC EC66 and EC67 CCIN 2CF3 Adapter part number 01FT742 4 3 2 3 EC6E1 PCIe4 x16 1 port HDR 100 Gb InfiniBand ConnectX 6 adapter FC EC6E CCIN 590D Adapter part number 02CM915 8335 GTH Direct Attach Copper DAC cables 4 3 2 Active Optical Cables AOC cables 4 3 8335...

Page 36: ...if software for fixes are available use the IBM Power Systems Prerequisite website https www14 software ibm com support customercare iprt home Table 5 PCIe adapters supported in the 8335 GTG 8335 GTH or 8335 GTX system Feature code Description EC2R PCIe3 2 port 10 Gb NIC and RoCE SR CU adapter FC EC2R and EC2S CCIN 58FA Adapter FRU number 01FT759 EC2T PCIe3 2 port 25 10 Gb NIC and RoCE SR CU capab...

Page 37: ... RJ45 adapter FC EN0V CCIN 2CC3 Adapter FRU number 00E2715 1 The adapter is only supported on the 8335 GTH and 8335 GTX systems PCIe3 2 port 10 Gb NIC RoCE SR Cu adapter FC EC2R and EC2S CCIN 58FA Learn about the specifications and operating system requirements for feature code FC EC2R and EC2S adapters Overview FC EC2R and EC2S are both the same adapter with different feature codes FC EC2R is a l...

Page 38: ...Figure 14 PCIe3 LP 2 port 10 Gb NIC RoCE SR Cu Adapter FC EC2R 24 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 39: ...9314 Optical wrap plug I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V 12 V Installing and configuring the 8335 GTX 25 ...

Page 40: ...pter cabling see the Cable and Transceiver information on page 26 Transceivers IBM qualifies and supports SFP optical transceiver FC EB46 to install into the adapter Customers can also use their own optical cabling and SFP optical transceiver for the other end The 10 Gb optical transceiver is capable up to 300 M through the OM3 cable or 82 M through OM2 cable Either one or both of the adapter s tw...

Page 41: ...r http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags info ...

Page 42: ...Figure 16 PCIe3 LP 2 port 25 10 Gb NIC RoCE SFP28 Adapter FC EC2T 28 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 43: ...2R9314 Optical wrap plug I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V 12 V Installing and configuring the 8335 GTX 29 ...

Page 44: ...re information about adapter cabling see Cable and Transceiver information on page 30 Transceivers For 25 GbE IBM qualifies and supports SFP28 optical transceiver FC EB47 to install into the adapter Customers can also use their own optical cabling and SFP28 optical transceiver for the other end The 25 Gb optical transceiver is capable up to 100 m through the OM4 cable or 70 M through OM3 cable Eit...

Page 45: ... to SFP28 4x25 Gb Ethernet split cable EN01 10 Gb s 1 m 3 3 ft copper active twinax Ethernet cable EN02 10 Gb s 3 m 9 8 ft copper active twinax Ethernet cable EN03 10 Gb s 5 m 16 4 ft copper active twinax Ethernet cable EN03 10 Gb s 5 m 16 4 ft copper active twinax Ethernet cable Operating system or partition requirements If you are installing a new feature ensure that you have the software that i...

Page 46: ... ports The PCIe3 2 port 100 GbE NIC and RoCE QSFP28 Adapter supports both NIC Network Interface Controller and IBTA RoCE standards RoCE is Remote Direct Memory Access RDMA over Converged Ethernet Using RoCE the adapter can support significantly greater bandwidth with low latency It also minimizes CPU overhead by more efficiently using memory access This offloads the CPU from I O networking tasks i...

Page 47: ...r FC EB59 to install into the adapter Customers can also use their own optical cabling and QSP28 optical transceiver for the other end This is a 100Gbase SR4 based active optical transceiver capable up to 100 M through the OM4 cable or 70 M through OM3 cable Either one or both of the adapter s two QSP28 ports can be populated When two ports are filled both can have copper cables or optical cables ...

Page 48: ...working tasks Minimizes CPU overhead by more efficiently using memory access Operating system or partition requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements ...

Page 49: ...ly oriented write operations are performed instead of random write operations the maximum write capacity will be large To extend the life of the NVMe device the application that is using the NVMe device must convert small random write operations to larger sequential write operations The write operations that exceed the maximum write capacity of the adapter continues to operate for some time but th...

Page 50: ...ent For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V 12 V 36 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 51: ...apters FC EC5C and EC5D are supported on AIX or Linux operating systems FC EC6W and EC6X are supported on the IBM i operating system Overview The PCIe3 x8 NVMe 1 6 TB SSD NVMe adapter is a Peripheral Component Interconnect Express PCIe generation 3 Gen3 x8 adapter The adapter can be used in either a x8 or x16 PCIe Gen3 slot in the system and uses Non Volatile Memory Express NVMe NVMe is a high per...

Page 52: ...Me Flash Adapter Specifications Item Description Adapter FRU number 01LK431 I O bus architecture PCIe3 x8 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on 38 Power Systems Installing the System ...

Page 53: ...g system requirements for feature code FC EC5E EC5F EC6Y and EC6Z adapters FC EC5E and EC6Y are low profile adapters and EC5F and EC6Z are full height adapters FC EC5E and EC5F are supported on AIX or Linux operating systems FC EC6Y and EC6Z are supported on the IBM i operating system Overview The PCIe3 x8 NVMe 1 6 TB SSD NVMe adapter is a Peripheral Component Interconnect Express PCIe generation ...

Page 54: ...lications where the content in the adapter must be protected additional NVMe Flash adapters with OS mirroring or software Redundant Array of Independent Disks RAID are recommended This adapter is not supported in the PCIe Gen3 I O drawer Figure 21 PCIe3 x8 NVMe 6 4 TB SSD NVMe Flash Adapter Specifications Item Description Adapter FRU number 01LK435 I O bus architecture PCIe3 x8 40 Power Systems In...

Page 55: ...ixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the NVMe management tool can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For s...

Page 56: ...e4 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on 42 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 57: ...tomercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert webs...

Page 58: ...e4 x16 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on 44 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 59: ... SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software...

Page 60: ...Figure 24 2 port 100 GbE RoCE En Connectx 5 Gen4 PCIe x16 adapter FC EC66 46 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 61: ... p9eab_mtm_pciplacement htm and select the system you are working on Cables For 100G IBM offers either Direct Attach Copper DAC cables up to 2 M or Active Optical Cables AOC up to 100 M QSFP28 based transceivers are included on each end of these cables For more information about adapter cabling see the CHANGE TO LINK Cable and transceiver matrix Note For 40G IBM offers DAC cables up to 3 M QSFP ba...

Page 62: ...ransceiver matrix Feature Description EB59 100Gbase SR4 optical transceiver MTP MPO cable purchased separately FC EB2J 10 M FC EB2K 30 M EB5J QSFP28 Passive Copper 100 Gb Ethernet Cable 5 M EB5K QSFP28 Passive Copper 100 Gb Ethernet Cable 1 M EB5L QSFP28 Passive Copper 100 Gb Ethernet Cable 1 5 M EB5M QSFP28 Passive Copper 100 Gb Ethernet Cable 2 M EB5R QSFP28 AOC 100 Gb Ethernet Cable 3 M EB5S QS...

Page 63: ...software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support deta...

Page 64: ...The Virtual Protocol Interconnect VPI feature is not supported on this adapter The adapter must be used only as an InfiniBand adapter Figure 26 1 port HDR 100 Gb InfiniBand ConnectX 6 adapter FC EC6E Specifications Item Description Adapter FRU number 02CM915 I O bus architecture PCIe4 x16 50 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 65: ...cables that are listed in the table support connecting to an HDR 100 Gb adapter to an HDR 200 Gb switch Note An HDR 200 Gb switch port must be in split mode configuration when using the HDR 100 Gb splitter cables Table 12 Cable matrix Feature Description EB50 Copper EDR 100 GbE cable 0 5 M EB51 Copper EDR 100 GbE cable 1 M EB54 Copper EDR 100 GbE cable 1 5 M EB52 Copper EDR 100 GbE cable 2 M EB5A ...

Page 66: ... Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see the Linux Alert website http www14 software ibm com webapp set2 sas f lopdiags...

Page 67: ...or more details Note The Virtual Protocol Interconnect VPI feature is not supported on this adapter The adapter must be used only as an InfiniBand adapter Figure 27 2 port HDR 100 Gb InfiniBand ConnectX 6 adapter FC EC6G Specifications Item Description Adapter FRU number 02CM912 I O bus architecture PCIe4 x16 Installing and configuring the 8335 GTX 53 ...

Page 68: ...he table support connecting to an HDR 100 Gb adapter to an HDR 200 Gb switch Note An HDR 200 Gb switch port must be in split mode configuration when using the HDR 100 Gb splitter cables Table 13 Cable matrix Feature Description EB50 Copper EDR 100 GbE cable 0 5 M EB51 Copper EDR 100 GbE cable 1 M EB54 Copper EDR 100 GbE cable 1 5 M EB52 Copper EDR 100 GbE cable 2 M EB5A Optical EDR 100 GbE cable 3...

Page 69: ...e ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM Service and Productivity Tools website http www14 software ibm com webapp set2 sas f lopdiags home html For support details see...

Page 70: ... interface The adapter supports integrated media access control MAC and physical layer PHY The adapter supports the following standards for the different ports and functions IEEE 802 3ae in the 10 GbE ports 802 3ab in the 1 GbE ports Ether II and IEEE 802 3 for encapsulated frames 802 1p for setting up priority levels in tagged VLAN frames 802 1Q for VLAN tagging 802 3x for flow control 802 3ad fo...

Page 71: ...Figure 28 PCIe2 2 port 10 GbE BaseT RJ45 adapter FC EL55 or FC EN0W Figure 29 PCIe2 LP 2 port 10 GbE BaseT RJ45 adapter FC EL3Z or FC EN0X Installing and configuring the 8335 GTX 57 ...

Page 72: ... utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM Power RAID adapter utilities iprutils can be downloaded from the IBM...

Page 73: ...sage information Provides a large payload size of 2048 bytes for read and write functions Provides a large read request size of 4096 bytes The adapter is compatible with 4 8 and 16 Gb Fibre Channel interface with the following characteristics Provides for automatic negotiation between 4 Gb 8 Gb or 16 Gb link attachments Provides support for the following Fibre Channel topologies point to point 16G...

Page 74: ...purchased from IBM I O bus architecture PCIe base and CEM 3 0 x8 PCIe bus interface Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V 12 V 60 Power Systems Installing the System and...

Page 75: ...bps 0 5 70 m 1 64 229 65 ft 0 5 150 m 1 64 492 12 ft 0 5 380 m 1 64 1246 71 ft 0 5 400 m 1 64 1312 34 ft 8 Gbps 0 5 21 m 1 64 68 89 ft 0 5 50 m 1 64 164 04 ft 0 5 150 m 1 64 492 12 ft 0 5 190 m 1 64 623 36 ft 16 Gbps 0 5 15 m 1 64 49 21 ft 0 5 35 m 1 64 114 82 ft 0 5 100 m 1 64 328 08 ft 0 5 125 m 1 64 410 10 ft Adapter LED states Green and yellow LEDs can be seen through openings in the mounting ...

Page 76: ... ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentr...

Page 77: ...ps network attachment The cables are attached to the copper RJ45 connectors Each port is independent of one another and supports full duplex or half duplex The half duplex mode does not support a speed of 1000 Mbps The adapter provides the following features Supports interrupt moderation to deliver increased performance while significantly reducing processor utilization Supports dual port operatio...

Page 78: ...Figure 31 FC 5260 and FC EL4M PCIe2 4 port 1 GbE adapter 64 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 79: ...BM I O bus architecture PCIe2 x4 Slot requirement For details about slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V Form factor short low profile Connector information Two RJ 45 ports Installing and configuring the...

Page 80: ...rating system or partition requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and partition requirements see one of the following topics The latest version of enabling libraries and uti...

Page 81: ...nnel functions simultaneously Each port provides single initiator capability over a fiber link or with NPIV multiple initiator capabilities is provided The ports are SFP and include an optical SR transceiver The ports have LC type connectors and use shortwave laser optics The adapter operates at link speeds of 4 8 16 and 32 Gbps and automatically negotiates to the highest speed possible Each port ...

Page 82: ...bout slot priorities maximums and placement rules see PCIe adapter placement rules and slot priorities http www ibm com support knowledgecenter POWER9 p9eab p9eab_mtm_pciplacement htm and select the system you are working on Voltage 3 3 V 12 V Form factor Short low profile 68 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 83: ...uxAlerts html PCIe2 4 port 10 Gb 1 GbE SR Copper SFP RJ45 adapter FC EN0S FC EN0T FC EN0U and FC EN0V CCIN 2CC3 Learn about the specifications and operating system requirements for the feature code FC EN0S FC EN0T FC EN0U and FC EN0V adapters Overview The PCIe2 4 port 10 Gb 1 GbE SR Copper SFP RJ45 adapter is a PCI Express PCIe generation 2 Gen2 x8 short form factor adapter The FC EN0S and EN0U ar...

Page 84: ...ess control MAC per interface The adapter supports integrated media access control MAC and physical layer PHY The adapter supports the following standards for the different ports and functions IEEE 802 3ae in the 10 GbE ports 802 3ab in the 1 GbE ports Ether II and IEEE 802 3 for encapsulated frames 802 1p for setting up priority levels in tagged VLAN frames 802 1Q for VLAN tagging 802 3x for flow...

Page 85: ...2 4 Port 10 Gb 1 GbE SR Copper SFP RJ45 adapter FC EN0S and FC EN0U Note The ports are numbered from top to bottom as T1 T2 and so on for the AIX and IBM i operating systems Installing and configuring the 8335 GTX 71 ...

Page 86: ... Adapter FRU number 00E2715 Regular height tailstock part number 00E2863 Low profile tailstock part number 00E2720 Wrap plug FRU number 12R9314 SFP SR wrap plug 10N7405 1 Gb UTP wrap plug Note These wrap plugs are not included with the card 12R9314 FC ECW0 is the only wrap plug that can be purchased from IBM I O bus architecture PCIe2 x8 72 Power Systems Installing the System and Ordered Parts for...

Page 87: ...rs to 33 meters 1 64 feet to 108 26 feet 0 5 meters to 82 meters 1 64 feet to 269 02 feet 0 5 meters to 300 meters 1 64 feet to 984 25 feet Operating system or partition requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For...

Page 88: ...pecification and is supported for distances of up to 100 meters In addition to 1 Gb 1000 Mb networks 100 Mb networks are also supported The adapter provides the following features The adapter is a PCIe3 NIC network convergence adapter The 10 Gb SR ports can function in the NIC mode The adapter can be used as the host local area network LAN adapter The adapter supports interrupt moderation to deliv...

Page 89: ...d from top to bottom of the adapter as T1 T2 and so on for the AIX and IBM i operating systems Specifications Item Description Adapter FRU number 00E2715 Low profile tailstock part number 00E2720 Wrap plug FRU number 12R9314 SFP SR wrap plug 10N7405 1 Gb UTP wrap plug Note These wrap plugs are not included with the card 12R9314 FC ECW0 is the only wrap plug that can be purchased from IBM Installin...

Page 90: ... 0 5 meters to 82 meters 1 64 feet to 269 02 feet 0 5 meters to 300 meters 1 64 feet to 984 25 feet Operating system or partition requirements If you are installing a new feature ensure that you have the software that is required to support the new feature and that you determine whether any prerequisites must be met for this feature and attaching devices For information about operating system and ...

Page 91: ...nces of up to 100 meters In addition to 1 Gb 1000 Mb networks 100 Mb networks are also supported The adapter provides the following features The adapter is a PCIe2 NIC network convergence adapter The 10 Gb ports can function in the NIC mode The adapter can be used as the host local area network LAN adapter The adapter supports interrupt moderation to deliver increased performance while significant...

Page 92: ...fications Item Description Adapter FRU number 00E2715 Low profile tailstock part number 00E2720 Wrap plug FRU number 74Y7010 Twinax wrap plug 10N7405 1 Gb UTP wrap plug Note Wrap plugs are not included with the card and cannot be purchased from IBM I O bus architecture PCIe2 x8 78 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 93: ...of the following topics The latest version of enabling libraries and utilities can be downloaded from Fix Central http www ibm com support fixcentral Power Systems Prerequisites http www14 software ibm com support customercare iprt home IBM SSIC System Storage Interoperation Center http www 03 ibm com systems support storage ssic interoperability wss The latest version of the device driver or IBM ...

Page 94: ...arge from damaging your hardware When you use an ESD wrist strap follow all electrical safety procedures An ESD wrist strap is used for static control It does not increase or decrease your risk of receiving electric shock when using or working on electrical equipment If you do not have an ESD wrist strap just prior to removing the product from ESD packaging and installing or replacing hardware tou...

Page 95: ...cover 4 If needed label and remove any plugs that extend out of the PCIe adapter 5 Insert the adapter aligning it properly and inserting it fully into the slot as shown in Figure 40 on page 82 Installing and configuring the 8335 GTX 81 ...

Page 96: ... system Learn about the common procedures related to installing removing and replacing features in the system Before you begin Observe these precautions when you are installing removing or replacing features and parts About this task These precautions are intended to create a safe environment to service your system and do not provide steps for servicing your system The installation removal and rep...

Page 97: ...se one hand only to connect or disconnect signal cables Never turn on any equipment when there is evidence of fire water or structural damage Do not attempt to switch on power to the machine until all possible unsafe conditions are corrected Assume that an electrical safety hazard is present Perform all continuity grounding and power checks specified during the subsystem installation procedures to...

Page 98: ...the slide rail mounted equipment in the installation position Each rack cabinet might have more than one power cord For AC powered racks be sure to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing For racks with a DC power distribution panel PDP turn off the circuit breaker that controls the power to the system unit s or disconnect the customer s DC...

Page 99: ... the rack is not bolted to the floor Do not pull out more than one drawer at a time The rack might become unstable if you pull out more than one drawer at a time For fixed drawers This drawer is a fixed drawer and must not be moved for servicing unless specified by the manufacturer Attempting to move the drawer partially or completely out of the rack might cause the rack to become unstable or caus...

Page 100: ...azardous voltages disconnect all power cords and power cables L003 L005 CAUTION Hazardous energy present Voltages with hazardous energy might cause heating when shorted with metal which might result in splattered metal burns or both L005 86 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 101: ...d States see the Directory of worldwide contacts http www ibm com planetwide 7 If you encounter difficulties during the installation contact your service provider your IBM reseller or your next level of support 8 For the IBM Power System AC922 8335 GTC 8335 GTG and 8335 GTH or IBM Power System AC922 8335 GTW and 8335 GTX systems ensure that the top cover is on when the system is running for therma...

Page 102: ...Figure 41 Front LEDs with bezel on Figure 42 Front LEDs with bezel off 88 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 103: ...335 GTH 8335 GTW or 8335 GTX system that needs servicing Learn how to turn on the blue identify LED to help you find the system that needs servicing Procedure To activate the blue system identify LED use the following command openbmctool U username P password H BMC IP address or BMC host name chassis identify on To turn off the blue system identify LED use the following command openbmctool U usern...

Page 104: ... does not increase or decrease your risk of receiving electric shock when using or working on electrical equipment If you do not have an ESD wrist strap just prior to removing the product from ESD packaging and installing or replacing hardware touch an unpainted metal surface of the system for a minimum of 5 seconds If at any point in this service process you move away from the system it is import...

Page 105: ...or or or or Installing and configuring the 8335 GTX 91 ...

Page 106: ...5 9 Remove the power supplies from the system as shown in Figure 44 on page 93 a To release a power supply from its position in the system pull the locking tab A to the left b Grasp the power supply handle with one hand and pull the power supply B partially out of the system c Place your other hand underneath the power supply and pull the power supply out of the system and place it on an ESD mat d...

Page 107: ...service position on page 101 CAUTION Do not place any object on top of a rack mounted device unless that rack mounted device is intended for use as a shelf R008 L012 CAUTION Pinch hazard L012 11 Remove the service access cover For instructions see Removing the service access cover from an 8335 GTC 8335 GTG 8335 GTH 8335 GTW or 8335 GTX system on page 98 Installing and configuring the 8335 GTX 93 ...

Page 108: ...er on an 8335 GTC 8335 GTG 8335 GTH 8335 GTW or 8335 GTX system on page 99 3 Place the system into the operating position For instructions see Placing an 8335 GTC 8335 GTG 8335 GTH 8335 GTW or 8335 GTX system into the operating position on page 103 L012 CAUTION Pinch hazard L012 Attention For a water cooled system before you power on the system ensure that cooling water is circulating through the ...

Page 109: ...9 Configure the BMC IP address For instructions see Configuring the BMC IP address www ibm com support knowledgecenter POWER9 p9eih p9eih_configuring_bmc_ip htm 10 Enter the network settings that you recorded earlier For instructions see Network settings www ibm com support knowledgecenter POWER9 p9eih p9eih_openbmc_networksetting htm 11 Replace the front cover For instructions see Installing the ...

Page 110: ... the system or you can use a console to power on the system Procedure 1 Open the front rack door if necessary 2 Before you press the power button ensure that the power supplies are connected to the system unit and verify the following items All system power cables are connected to a power source The power on LED as shown in Figure 46 on page 96 is flashing A flashing light indicates standby power ...

Page 111: ... can check the sensor status to quickly determine the general health of the system without using the event codes To view the sensor status use the following command openbmctool U username P password H BMC IP address or BMC host name fru status To view the sensor status and any corresponding event codes use the following command openbmctool U username P password H BMC IP address or BMC host name fr...

Page 112: ...service access cover complete the steps in this procedure Procedure 1 Ensure that you removed both power supplies from the system For instructions see Preparing the 8335 GTC 8335 GTG 8335 GTH 8335 GTW or 8335 GTX system to remove and replace internal parts on page 90 L005 CAUTION Hazardous energy present Voltages with hazardous energy might cause heating when shorted with metal which might result ...

Page 113: ...W or 8335 GTX system To replace the service access cover complete the steps in this procedure About this task Attention For safety airflow purposes and thermal performance the service access cover must be installed and fully seated before powering on the system on Procedure 1 Place the cover A on the system unit such that the alignment pins on the cover are aligned to the slots on the chassis Slid...

Page 114: ... 2 Ensure that you have the electrostatic discharge ESD wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface If not do so now 3 If applicable remove the screws that are on both sides of the cover to disengage the cover from the system unit 4 Pull the cover away from the system 100 Power Systems Installing the System and Ordered Parts for the...

Page 115: ...5 GTX system into the service or operating position Placing an 8335 GTC 8335 GTG 8335 GTH 8335 GTW or 8335 GTX system into the service position To place a system into the service position complete the steps in this procedure About this task Pick the proper type of rails for your system Slide rails on page 101 Fixed rails on page 102 Slide rails Use this procedure when your system is installed usin...

Page 116: ...he rack Note When you place the system into the service position you must ensure that all stability plates are firmly installed to prevent the rack from toppling Ensure that only one system unit is removed at a time Procedure 1 Label and disconnect the cables at the rear of the system unit 2 For a water cooled system label and disconnect the water hoses at the manifold Pull the coupling toward you...

Page 117: ...n the left side of the system and one person on the right side of the system 6 Tilt and lift the system from the rails 7 Carefully set the system on a table with an appropriate ESD surface Placing an 8335 GTC 8335 GTG 8335 GTH 8335 GTW or 8335 GTX system into the operating position To place a system into the operating position complete the steps in this procedure About this task Pick the proper ty...

Page 118: ...rocedure 1 Unlock the blue rail safety latches A by lifting them upward 2 Align the system unit on to the rails and push the system unit back into the rack until both release latches lock into position See Figure 52 on page 104 Figure 52 Placing the system into the operating position 3 Replace the screws on either side of the system that secure the system to the rack 104 Power Systems Installing t...

Page 119: ...of the system 2 Lift the system 3 Tilt the system into position over the fixed rack rails 4 Carefully lower the system until the rear of the system rests on the rails 5 While one person is supporting the weight of the system have the second person move to the front of the system and push the system all the way into the rack 6 Using your labels reconnect the cables at the rear of the system unit 7 ...

Page 120: ...335 GTW or 8335 GTX system To disconnect a power cord complete the steps in this procedure Procedure 1 Open the rear rack door on the system unit that you are servicing 2 Identify the system unit that you are servicing in the rack 3 Label and disconnect the power cords from the power supply handle Unfasten the hook and loop fastener that ties the power cord to the power supply handle Note how the ...

Page 121: ...Figure 54 Routing the power cord loop in the cable management arm Installing and configuring the 8335 GTX 107 ...

Page 122: ...56 on page 109 Note This system might be equipped with two or more power supplies If the removing and replacing procedures require the power to be off then ensure that all the power sources to the system are disconnected 108 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 123: ...ur labels reconnect the power cords to the system unit as shown in Figure 57 on page 109 Figure 57 Connecting the power cords to the system 3 Loop and attach the power cords to the power supply handle Note how the power is looped be sure to maintain at least a 5 cm 2 in diameter loop Use the hook and loop fastener to tie the power cord to the power supply handle Figure 58 on page 110 and Figure 59...

Page 124: ...Figure 58 Routing the power cord loop in the cable management arm 110 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 125: ...Figure 59 Power cord loop with sidewall routing 4 Close the rack door at the rear of the system Installing and configuring the 8335 GTX 111 ...

Page 126: ...112 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 8335 GTX ...

Page 127: ...uct s and or the program s described in this publication at any time without notice Any references in this information to non IBM websites are provided for convenience only and do not in any manner serve as an endorsement of those websites The materials at those websites are not part of the materials for this IBM product and use of those websites is at your own risk IBM may use or distribute any o...

Page 128: ...nology content successfully Overview The IBM Power Systems servers include the following major accessibility features Keyboard only operation Operations that use a screen reader The IBM Power Systems servers use the latest W3C Standard WAI ARIA 1 0 www w3 org TR wai aria to ensure compliance with US Section 508 www access board gov guidelines and standards communications and it about the section 5...

Page 129: ...provide you as the customer the ability to collect personally identifiable information from end users via cookies and other technologies you should seek your own legal advice about any laws applicable to such data collection including any requirements for notice and consent For more information about the use of various technologies including cookies for these purposes see IBM s Privacy Policy at h...

Page 130: ...nie 2014 30 EU zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU Mitgliedsstaatenund hält die Grenzwerte der EN 55022 EN 55032 Klasse A ein Um dieses sicherzustellen sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden IBM übernimmt keine Verantwo...

Page 131: ...relle Informationen Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 EN 55032 Klasse A Japan Electronics and Information Technology Industries Association JEITA Notice This statement applies to products less than or equal to 20 A per phase This statement applies to products greater than 20 A single phase This statement applies to products greater than 20 A per phase three phase...

Page 132: ... energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC e...

Page 133: ...ding the fitting of non IBM option cards German Notice Deutschsprachiger EU Hinweis Hinweis für Geräte der Klasse B EU Richtlinie zur Elektromagnetischen Verträglichkeit Dieses Produkt entspricht den Schutzanforderungen der EU Richtlinie 2014 30 EU zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU Mitgliedsstaatenund hält die Grenzwerte der EN 55022 EN 55...

Page 134: ...gen nach EN 55024 und EN 55032 Klasse B Japan Electronics and Information Technology Industries Association JEITA Notice This statement applies to products less than or equal to 20 A per phase This statement applies to products greater than 20 A single phase This statement applies to products greater than 20 A per phase three phase Japan Voluntary Control Council for Interference VCCI Notice 120 P...

Page 135: ...o or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference ...

Page 136: ...he above instructions are not being properly followed You may not download export or re export this information except in full compliance with all applicable laws and regulations including all United States export laws and regulations IBM MAKES NO GUARANTEE ABOUT THE CONTENT OF THESE PUBLICATIONS THE PUBLICATIONS ARE PROVIDED AS IS AND WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLU...

Page 137: ......

Page 138: ...IBM ...

Reviews: