• When you use an ESD wrist strap, follow all electrical safety procedures. An ESD wrist strap is
used for static control. It does not increase or decrease your risk of receiving electric shock
when using or working on electrical equipment.
• If you do not have an ESD wrist strap, just prior to removing the product from ESD packaging
and installing or replacing hardware, touch an unpainted metal surface of the system for a
minimum of 5 seconds. If at any point in this service process you move away from the
system, it is important to again discharge yourself by touching an unpainted metal surface for
at least 5 seconds before you continue with the service process.
2. If the time-of-day battery is covered by a PCIe adapter, move the PCIe adapter out of the way.
For instructions, see “Removing a PCIe adapter from the 9006-12P system” on page 29.
3. Remove the time-of-day battery (A) by pushing the tab (B) away from the battery as shown in Figure
69 on page 76.
When you remove the battery, do not use a metallic tool to disengage it from its slot.
Figure 69. Removing the time-of-day battery
4. Replace the time-of-day battery (A).
The orientation of the + of the battery is up as shown in the following figure.
76 Power Systems: Servicing the IBM Power System LC921 (9006-12P)