CAUTION: Hazardous energy present. Voltages with hazardous energy might cause heating
when shorted with metal, which might result in splattered metal, burns, or both. (L005)
6. Place the system into the service position. For instructions, see “Placing an 9006-12P system into the
CAUTION: Do not place any object on top of a rack-mounted device unless that rack-mounted
device is intended for use as a shelf. (R008)
(L012)
CAUTION: Pinch hazard. (L012)
7. Remove the service access cover. For instructions, see “Removing the service access cover from an
Preparing the 9006-12P system for operation after you remove and replace
internal parts
Learn how to prepare the IBM Power System LC921 (9006-12P) system for operation after you remove
and replace internal parts.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. Replace the service access cover. For instructions, see “Installing the service access cover on an
3. Place the system into the operating position. For instructions, see “Placing an 9006-12P system into
the operating position” on page 101.
(L012)
CAUTION: Pinch hazard. (L012)
4. Reconnect the power cords to the system. For instructions, see “Connecting the power cords to the
5. Start the system. For instructions, see “Starting the 5104-22C, 9006-12P, 9006-22C, or 9006-22P
6. If you installed or replaced a PCIe adapter, update the adapter firmware.
See Getting firmware fixes for vendor I/O adapters from the vendor website (www.ibm.com/support/
knowledgecenter/POWER9/p9ei8/p9ei8_update_other_adapter.htm).
7. Verify the installed part.
Common procedures for servicing or installing features in the 9006-12P 89
Summary of Contents for Power System LC921 9006-12P
Page 1: ...Power Systems Servicing the IBM Power System LC921 9006 12P IBM...
Page 14: ...xiv Power Systems Servicing the IBM Power System LC921 9006 12P...
Page 118: ...104 Power Systems Servicing the IBM Power System LC921 9006 12P...
Page 120: ...106 Power Systems Servicing the IBM Power System LC921 9006 12P...
Page 131: ......
Page 132: ...IBM...