Figure 39. Lifting out the system backplane
13. Place the system backplane on an ESD mat.
Replacing the system backplane in the 9006-12P system
Learn how to replace the system backplane in the IBM Power System LC921 (9006-12P) system.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. Remove the replacement system backplane from the static-protective package and place it on an
ESD mat.
3. Ensure that the jumper setting at the indicated location is set as shown in Figure 40 on page 46,
over pins 1 and 2.
Pin 3 is closest to the front of the system. Pin 1 is closest to the rear of the system.
Removing and replacing parts in the 9006-12P system 45