Adapter specifications
Item
Description
FRU number
10N9824 (Designed to comply with RoHS requirement)
Wrap plug FRU number
12R9314 (Designed to comply with RoHS requirement)
11P3847 (Not designed to comply with RoHS requirement)
I/O bus architecture
PCI Express (PCIe) Base and Card Electromechanical (CEM) 2.0 x8 PCIe bus interface
Slot requirement
One available PCIe x8 or x16 slot
Voltage
3.3 V
Form factor
Short, low-profile
FC compatibility
2, 4, 8 Gigabit
Cables
Cables are the responsibility of the customer.
Use multimode fiber optic cables with shortwave lasers that adhere to the following
specifications:
v
OM3: Multimode 50/125 micron fiber, 2000 MHz x km bandwidth
v
OM2: Multimode 50/125 micron fiber, 500 MHz x km bandwidth
v
OM1: Multimode 62.5/125 micron fiber, 200 MHz x km bandwidth
Because core sizes are different, OM1 cables can only be connected to other OM1 cables. For best
results, OM2 cables should not be connected to OM3 cables. However, if an OM2 cable is
connected to an OM3 cable, the characteristics of the OM2 cable apply to the entire length of the
cables. The following table shows the supported distances for the different fiber optic cable types
at different link speeds.
Table 9. Supported distances for multimode fiber optic cables
Header
Cable Type and Distance
Rate
OM1
OM2
OM3
2.125 Gbps
0.5 meters to 150 meters
(1.64 feet to 492.12 feet)
0.5 meters to 300 meters
(1.64 feet to 984.25 feet)
0.5 meters to 500 meters
(1.64 feet to 1640.41 feet)
4.25 Gbps
0.5 meters to 70 meters
(1.64 feet to 229.65 feet)
0.5 meters to 150 meters
(1.64 feet to 492.12 feet)
0.5 meters to 380 meters
(1.64 feet to 1246.71 feet)
8.5 Gbps
0.5 meters to 21 meters
(1.64 feet to 68.89 feet)
0.5 meters to 50 meters
(1.64 feet to 164.04 feet)
0.5 meters to 150 meters
(1.64 feet to 492.12 feet)
Maximum number
For details about the maximum number of adapters that are supported, see PCIe adapter
placement rules and slot priorities(http://www.ibm.com/support/knowledgecenter/POWER8/
p8eab/p8eab_mtm_pciplacement.htm) and select the system you are working on.
Operating system or partition requirements
If you are installing a new feature, ensure that you have the software that is required to support the new
feature and that you determine whether there are any prerequisites for this feature and attaching devices.
To check for the prerequisites, see IBM Prerequisite website (www-912.ibm.com/e_dir/eServerPrereq.nsf).
The adapter is supported on the following versions of the operating systems, depending on the system
you are using:
46
Installing the System and Ordered Parts for the 8348-21C
Summary of Contents for Power Systems S812LC 8348-21C
Page 2: ......
Page 6: ...iv Installing the System and Ordered Parts for the 8348 21C...
Page 16: ...xiv Installing the System and Ordered Parts for the 8348 21C...
Page 76: ...or or 1 2 3 4 or 1 2 3 4 or 60 Installing the System and Ordered Parts for the 8348 21C...
Page 88: ...72 Installing the System and Ordered Parts for the 8348 21C...
Page 108: ...92 Installing the System and Ordered Parts for the 8348 21C...
Page 109: ......
Page 110: ...IBM Printed in USA...