3.
Reboot the system.
4.
(Trained technician only) If the error continues, replace the planar.
80070201-0301xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 1
OverTemp)
Explanation:
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702010301xxxx or 0x800702010301xxxx
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
2.
Check the ambient temperature. You must be operating within the specifications (see Features and specifications
for more information).
3.
Make sure that the heat sink for microprocessor n is installed correctly.
4.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
80070201-0302xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 2
OverTemp)
Explanation:
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702010302xxxx or 0x800702010302xxxx
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
2.
Check the ambient temperature. You must be operating within the specifications (see Features and specifications
for more information).
3.
Make sure that the heat sink for microprocessor n is installed correctly.
4.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
80070201-0301xxxx • 80070201-0302xxxx
404
IBM System x3550 M4 Type 7914: Installation and Service Guide
Summary of Contents for Redboks System x3550 M4
Page 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 811: ...Taiwan Class A compliance statement Notices 793 ...
Page 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 819: ......
Page 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...