Step 1540-3
One of the FRUs remaining in the system unit is defective.
If the disk activity indicator LED is ON, exchange FRU's in this order:
1. System board
2. Memory module
3. CPU card
If the disk activity indicator LED is OFF, exchange FRU's in this order:
1. CPU card
2. System board
3. Memory module
The system is working correctly if it beeps twice (one short, and a minute or more
later, one long).
1. Turn the power off.
2. Exchange one of the FRUs in the list, based on the order you determined above.
3. Turn the power on.
Did the system beep twice?
NO
Reinstall the original FRU.
Repeat the FRU replacement steps until the defective FRU is identified or
all the FRUs have been exchanged.
If the symptom did not change and all the FRUs have been exchanged,
call your service support person for assistance.
If the symptom has changed, check for loose cards, cables, and obvious
problems. If you do not find a problem, return to “Step 1540-1” on
page 2-19 in this MAP and follow the instructions for the new symptom.
YES
Go to "Map 0410: Repair Checkout" in the
IBM RS/6000 Diagnostic
Information for Multiple Bus Systems.
Chapter 2. Maintenance Analysis Procedures
2-21
Summary of Contents for RS/6000 7024 E Series
Page 1: ...RS 6000 7024 E Series IBM Service Guide SA38 0502 03...
Page 5: ...Power Cables 8 5 Appendix A Firmware Checkpoint Three Digit Codes A 1 Index X 1 Preface v...
Page 6: ...vi Service Guide...
Page 18: ...xviii Service Guide...
Page 20: ...xx Service Guide...
Page 22: ...Rear View 1 2 Service Guide...
Page 23: ...Side View with Covers Removed Chapter 1 Reference Information 1 3...
Page 24: ...Recommended SCSI IDs 1 4 Service Guide...
Page 82: ...3 18 Service Guide...
Page 122: ...Replacement To replace the cover perform the removal steps in reverse order 7 6 Service Guide...
Page 148: ...7 32 Service Guide...
Page 149: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 150: ...8 2 Service Guide...