Step 1540-4
No failure was detected with this configuration.
1. Turn the power off.
2. Install a memory module.
3. Turn the power on.
4. Wait until the system beeps twice or the system appears to stop.
5. The system beeps once (one short).
6. The system does not beep.
Did the system beep twice?
NO
Go to “Step 1540-5.”
YES
Repeat this step until all the memory modules are installed and tested.
After all the memory modules are installed and tested, turn the power to
off.
Go to “Step 1540-7” on page 2-24.
Step 1540-5
The failure may be caused by the last memory module installed. To isolate the failing
FRU, do the following:
1. Turn the power off.
2. Exchange the last memory module installed.
3. Turn the power on.
Did the system beep twice?
NO
Go to “Step 1540-6” on page 2-23.
YES
Go to "Map 0410: Repair Checkout" in the
IBM RS/6000 Diagnostic
Information for Multiple Bus Systems.
2-22
Service Guide
Summary of Contents for RS/6000 7024 E Series
Page 1: ...RS 6000 7024 E Series IBM Service Guide SA38 0502 03...
Page 5: ...Power Cables 8 5 Appendix A Firmware Checkpoint Three Digit Codes A 1 Index X 1 Preface v...
Page 6: ...vi Service Guide...
Page 18: ...xviii Service Guide...
Page 20: ...xx Service Guide...
Page 22: ...Rear View 1 2 Service Guide...
Page 23: ...Side View with Covers Removed Chapter 1 Reference Information 1 3...
Page 24: ...Recommended SCSI IDs 1 4 Service Guide...
Page 82: ...3 18 Service Guide...
Page 122: ...Replacement To replace the cover perform the removal steps in reverse order 7 6 Service Guide...
Page 148: ...7 32 Service Guide...
Page 149: ...Chapter 8 Parts Information Chapter 8 Parts Information 8 1...
Page 150: ...8 2 Service Guide...