System Board Jumper Settings
For a more complete description of the function of these jumpers, see "Installing and
Removing Options" in the RS/6000 7046 Model B50 User's Guide.
Jumper
Description
Settings
J15
Remote Power-up
Default: Remote power-up disabled.
To enable Remote power-up, place
jumper on the two pins closest to the
rear of the server.
J20
Power-On Password
Default: power-on password enabled
(can be set).
To disable the power-on password
(for instance, if it has been forgotten),
place jumper on the two rightmost
pins.
J32
Privileged-Access Password
Default: disabled.
To enable the writing or changing of
the privileged-access password, place
jumper on the two pins closest to the
rear of the server.
J35, J36
SCSI Security
Default: external SCSI enabled
To disable external SCSI connector,
move the jumper on J35 to the front
two pins, and the jumper on J36 to
the right two pins.
1-8
7046 Model B50 Service Guide
All manuals and user guides at all-guides.com
all-guides.com
Summary of Contents for RS/6000 7046 B50
Page 2: ...All manuals and user guides at all guides com...
Page 8: ...vi 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 30: ...1 12 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 94: ...3 30 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 100: ...4 6 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 190: ...A 6 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 194: ...X 4 7046 Model B50 Service Guide All manuals and user guides at all guides com...
Page 197: ...All manuals and user guides at all guides com...